LUBExpert User Manual
45/52
Lubrication management. They can be automatically assigned by LUBExpert, or manually added by
operator. Automatically added messages are result of the alarm status/recommendation after initial
reading. Manually added messages represent operator´s actions opposite to
alarms/recommendations or field observations. Messages are clearly marked as automatically added
(A) or manually added (M). All messages displayed here are also displayed in static trend graph.
By selecting measurement level (sensor) in tree view and selecting Measurements tab in bottom
pane, you will have detailed information about each lubrication process performed in this Lube point.
This view gives many different information sets. You can customize your view in the Parameters
Menu. In the view displayed in the above screenshot, we see Alarm Level, RMS value for each
measurement, Lube Alarm Status, Lube Alarm Level Specified, Number of Shots Added, Quantity of
Added Grease in Grams (oz), Date and Time.
In case the lubrication process was performed through FREE MODE, each reading will be displayed:
first reading as INITIAL READING, all following readings as FREE MODE and final reading as Lube
Alarm Level (as an example LUBRICATION SUCCESS) Each step will be added grease quantity
displayed (added in that step), while final step will display total added quantity during the process.
Lube Alarm Level will have the letter “F” added, as an indication t
he process was performed in FREE
MODE
In case the Lubrication process was performed in GUIDED MODE only, first and final readings are
displayed. First reading is displayed as INITIAL READING and final reading is displayed with Lube
Alarm Level, and total quantity of added grease.
Here are some examples:
Initial reading of 59 dBµV RMS triggered alarm status “ALERT” (blue alarm sign) and indicated need
for lubrication. Final reading of 45 dBµV is below alarm level, so alarm icon is a green oil drop. Lube
alarm is displayed as green oil drop icon indicating a positive outcome of the lubrication task. Lube
Alarm Level says “Lubrication success” indicating that the process of lubrication improved friction
level (decreased it). 45 shots of grease were added, with 90 grams grease in total.