LUBExpert User Manual
22/52
Manual input of grease quantity
If you want to manually add calculated
grease quantity, chose “Edit” in field
⑦
and enter the quantity. In this case, all
pre-calculations will be done based on
your input. Manually edited quantity will
be shown in
Italic.
If you want to go back
to automatically calculated qty, simply
press the “go back” arrow in field
⑦
.
Note that the bearing must be selected, at least temporary one, with an approximate size. Editing
quantity by more than 30% might cause guidance malfunction.
Side or Annular replenishment
In field
⑥
, you need to choose if grease replenishment is side or
annular. Select “side” or “annular” from the drop
-down menu.
Note! If you chose to edit calculated grease quantity manually, this
field will be blocked.
Once you have selected a bearing that is actually installed in the asset as well as its replenishment
position, OD, ID and Width are defined, and grease quantity is calculated and adjusted according to
selected grease pump output. This quantity is used as
a safety point only in case of “Suspected
Bearing Failure” status and to provide automatic recommendation to “Shorten Interval” that you
have selected. Based on asset data selected at this point, UAS3 is also able to calculate steps in your
guided lubrication process. In this example, step one will be 5 shots injection, step two 3 shots, step
3 and all following steps 2 shots.
Setting rotational speed
In order to complete the setup, UAS3
also needs information about the
rotating speed of the selected asset.
Enter the rotational speed in RPM in
field
⑧
. In case you are not sure
about the rotating speed, or it is
variable, set the lowest expected
rotating speed to be on the safe side.
Acquisition time
Based on rotating speed, UAS3 will
automatically calculate minimum and
recommended acquisition time
⑨
.
Recommended time is the result of
positive experiences, but if desired,
you can choose minimum time or any
other acquisition time, but not less
than minimum time and not greater
than 80 seconds.
Stabilization time
Based on previously inserted data,
UAS3 now automatically calculates
the stabilization time and displays it in
field
⑩
.
⑧
⑨
⑩
Содержание FS.LBX.001