LUBExpert User Manual
35/52
•
In case for some reason, you decide to ignore the alarm recommendation (maybe some
safety risk was observed, and you decided to abort the process) and do not add grease, press
M
to
assign a message
, select message and press ENTER. Your message is now added to the
asset and marked as a manually added message. The following screen appears;
•
Only after assigning a message and from this screen, you can press
F1
and
EXIT
9.3.
Collecting dynamic data with LUBExpert app (SDT270DU & LUBExpert
Dynamic only)
If you are using LUBExpert Dynamic or SDT270DU with LUBExpert App, there is an additional
opportunity to collect Dynamic data (TWF, FFT) while performing your lubrication task through
LUBExpert procedures.
You can create your measurement node in two ways:
1.
You can create both Dynamic and Static settings in your measurement node.
Pay attention
that settings must be the same. To make it accurate, fast and easy, use copy/paste settings
functionality.
You can add both measurement settings to your Work Order/Survey, or just one of them.
In case you add only Dynamic settings to your Work Order/Survey, you will be able to perform your
task through Dynamic only, of course. Still, all static data will be populated to your Static point.
In case you add only Static settings to your Work Order/Survey, you will be able to perform your task
through Static only, of course. In this case, your Dynamic data will not be collected, and Dynamic
point will not be populated with data.
Содержание FS.LBX.001
Страница 51: ...LUBExpert User Manual 51 52 Notes...