background image

SCS

 

 
PTC-IIex 

 

The New Dimension in Data Transmission Technology 

 

 

Manual for Version 4.0 

 

 

 

 

©

 Copyright 2003-2009 

SCS

 GmbH & Co. KG 

Содержание PTC-IIex

Страница 1: ...SCS PTC IIex The New Dimension in Data Transmission Technology Manual for Version 4 0 Copyright 2003 2009 SCS GmbH Co KG...

Страница 2: ...und we ask your forgiveness and request you send us a short note pointing them out Your SCS Team Attention Very Important You should connect the power supply plug to the PTC IIex only when the power s...

Страница 3: ...to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation This...

Страница 4: ...nsceiver 10 3 3 1 Connection to ICOM transceivers 12 3 3 2 Connection to Kenwood transceivers 13 3 3 3 Connection to Yaesu transceivers 13 3 3 4 Amplitude Adjustment 14 4 LED s 17 4 1 PACTOR III 18 5...

Страница 5: ...ency 34 5 13 Audio Functions 35 5 14 The hostmode 35 6 Commands 37 6 1 ACheck AMTOR Check 37 6 2 ADdlf 37 6 3 Amtor 37 6 4 APower 38 6 5 AQrg 39 6 6 ARX 39 6 7 AUdio 40 6 8 BAKup 40 6 9 BAUdot 41 6 10...

Страница 6: ...6 52 LOGIn Remote 59 6 53 MAil 59 6 54 MARk 60 6 55 MAXDown 60 6 56 MAXErr 60 6 57 MAXSum 61 6 58 MAXTry 61 6 59 MAXUp 61 6 60 MOde 61 6 61 MONitor 62 6 62 MYcall 63 6 63 MYLevel 63 6 64 MYSelc 63 6...

Страница 7: ...Term 78 6 94 TIme Remote 80 6 95 TNC 81 6 96 TOnes 82 6 97 TR 83 6 98 TXDelay 83 6 99 UMlauts 84 6 100 Unproto 84 6 101 UPDATE 85 6 102 USer Remote 85 6 103 USOs Unshift On Space 86 6 104 VERIfy 86 6...

Страница 8: ...7 7 Comparator 104 8 7 8 PR300 105 8 8 Transmission during MODEM operation 105 8 8 1 Transmission in AM FAX Modem mode 105 8 8 2 Transmission in FM FAX FSK SSTV Modem mode 106 8 8 3 Transmission in C...

Страница 9: ...GIpeat 122 9 6 12 Disconnect 122 9 6 13 FRack 122 9 6 14 Help 123 9 6 15 JHOST 123 9 6 16 KISS 123 9 6 17 MAXframe 123 9 6 18 MCon 123 9 6 19 MFIlter 124 9 6 20 Monitor 124 9 6 21 MStamp 125 9 6 22 MT...

Страница 10: ...10 4 22 F 138 10 4 23 K 139 10 4 24 S 139 10 4 25 T2 139 10 4 26 T3 140 10 4 27 B 140 10 4 28 C 140 10 4 29 E 140 10 4 30 I 140 10 4 31 L 140 10 4 32 M 141 10 4 33 O 141 10 4 34 Q 141 10 4 35 T 141 10...

Страница 11: ...2 2 AUDPerm 156 12 3 Beep 157 12 4 DD 157 12 5 Fsk 157 12 6 Help 157 12 7 Kill 157 12 8 Led 157 12 9 MONitor 158 12 10 Ptt 158 12 11 PLl 158 12 12 Quit 158 12 13 Ram 158 13 The BIOS 160 13 1 BIOS and...

Страница 12: ...5 2 Why PACTOR II 171 15 3 Basics of the PACTOR II protocol 172 15 3 1 General 172 15 3 2 The modulation system 173 15 3 3 Error control coding 175 15 3 4 Online data compression 177 15 4 PACTOR II in...

Страница 13: ...3 6 KENWOOD 6 pin Mini DIN 13 Table 3 7 Yaesu connection 13 Table 3 8 YAESU 6 pin Mini DIN 14 Table 3 9 YAESU 6 pin Mini DIN 14 Table 4 1 PACTOR III Speedlevels 18 Table 5 1 Command prompts 20 Table 5...

Страница 14: ...List of Figures and Tables XII...

Страница 15: ...nal that provides an serial interface compatible with the RS232 V24 standard If you use a computer you need a appropriate terminal program to operate the serial interface with the following parameters...

Страница 16: ...nd your service provider The email client e g Airmail automaticly does most of the configurations needed and lets you successfully transfer email at a fraction of knowledge which this book presents So...

Страница 17: ...ail WIN Alpha WIN Easyterm EZT3271 WIN EasyTransfer WIN EasyUpdate WIN GSH PC DOS JVComm32 WIN JVFAX DOS Kptc Linux Mscan Meteo Fax WIN Mscan Meteo Pro WIN Mscan SSTV WIN Mscan for DOS DOS NCWinPTC WI...

Страница 18: ...the programs for the PC and the user manual The different version numbers are necessary to distinguish between old and new versions 1 5 3 File types Basicly the following file types extentions are us...

Страница 19: ...OR III can achieve its maximum speed with using unmodified common SSB transceivers The occupied bandwidth is around 2200 Hz Thus PACTOR III is the ideal means of fast and reliable data communication o...

Страница 20: ...ink Extreme compression of the TCP IP and PPP overhead Full PPP compatibility Use of common client server software like Netscape Outlook Eudora and others is possible Easy embedding and configuration...

Страница 21: ...63454 Hanau Germany Fax 49 6181 23368 Order Fax 49 6181 990238 EMail info scs ptc com Homepage Visit our Internet sites http www scs ptc com Here you will find Information to PACTOR and our modems The...

Страница 22: ...note to the shipment Do this always also if you have emailed us or talked to us previously Describe the problem as good as you can Write clearly Don t forget your return address If the PTC IIex shows...

Страница 23: ...a self resetting fuse 3 2 The serial interface RS232 V24 The SCS PACTOR controller communicates with the computer or terminal via a serial interface using the RS232 V24 standard For communication betw...

Страница 24: ...ifferent and has nothing whatsoever to do with simple FSK It is therefore IMPOSSIBLE to use the FSK modulators found in some transceivers to generate the signal The PACTOR II signal must always go via...

Страница 25: ...ver gives a power supply output via the AUX socket Th maximum of 0 3 A cable connec he PT IIex to PIN Color PIN Color 1 Violet 5 Blue 2 White 6 Red 3 Yellow 7 Black 4 Green 8 Brown Table 3 1 Cable Col...

Страница 26: ...n to ICOM transceivers Most ICOM transceivers that use 8 pin DIN plug ACC can be connected this way Signal PTC Color ICOM 8 pin GND PIN 2 white PIN 2 PTT PIN 3 yellow PIN 3 AF OUT PIN 1 violet PIN 4 A...

Страница 27: ...IN PIN 4 green PIN 6 Table 3 5 Kenwood TS 50 connection The TS 480 has a 6 pin Mini DIN connector Signal PTC Color YAESU GND PIN 2 white PIN 2 PTT PIN 3 yellow PIN 3 AF OUT PIN 1 violet PIN 1 AF IN P...

Страница 28: ...ice not the best way The audio input sensitivity of most transceivers is adapted to the output voltage of a common dynamic microphone 100 modulation is reached at low MIC Gain settings with 200 mV Pea...

Страница 29: ...t damage from the transceiver at continuous operation we recommend to limit the FSK output level to half of the maximum possible that means 50 W if the transceiver is made for 100 W at max 3 3 4 1 PAC...

Страница 30: ...3 Installation 16...

Страница 31: ...Send PTT lights when the PTC is actually the information sending station In Packet Radio mode Send PTT lights when the PTT is keyed and the transceiver is transmitting DQPSK DBPSK Is actice when rece...

Страница 32: ...After a firmware update the firmware needs to be copied to the 32 bit wide SRAM loading This condition is indicated with each second LED being on and off Update When the firmware or the BIOS are upda...

Страница 33: ...prompt is available immediately after the last command The PTC IIex is in the command mode The command mode is displayed with the system prompt cmd or pac During link set up and while connected the P...

Страница 34: ...ow significant mnemonics are printed in capital letters The short form of the SERBaud command is SERB 5 3 Menus The PTC IIex commands are combined into different function groups so called menus The di...

Страница 35: ...ise an error message is displayed When the command is accepted automaticly the DSP is switched to Packet Radio operation and the pac menu is activated In fact the PTC IIex automaticly loads the requir...

Страница 36: ...e Sysop Chapter 6 11 Check Lists actual mails Chapter 6 17 CLr Erase the transmit buffer Chapter 6 20 DAte Calls up the PTC date Chapter 6 33 DELete Erase a file or files Chapter 6 35 DIR Read the mai...

Страница 37: ...lo g c heck cl r l ist s end be ll u ser pos ition characters within brackets are optional For more information type h command eg help send next Display 5 7 1 PACTOR mailbox help At Read and Send comm...

Страница 38: ...ion Requests GPS position Chapter 6 72 Table 5 3 PACTOR mailbox commands Of course it is possible to enter mailbox commands on the console With the DIR and LIst command you can check the mailbox conte...

Страница 39: ...MYCALL 8 either at the first start when the Flash Call in the BIOS has been defined or when ones own PACTOR MYCALL has been set If for example DL1ZAM is given as the first PACTOR MYCALL then the PR ma...

Страница 40: ...n to without problem AUTO BIN transfer or similar protocols are at present not supported by the PR mailbox Uppercase and lowercase letters are not distinguished in the command processing All commands...

Страница 41: ...ty input only Return interrupts the file read operation User Lists the presently active links similar to the CStatus command in the pac menu A presently active PACTOR link is displayed in channel 0 of...

Страница 42: ...energy supply of a small ship A NAVTEX controller should therefore be able to operate without any additional computer and use little electrical energy itself The NAVTEX processor of the PTC IIex solv...

Страница 43: ...bers in consecutive operation An exception can occur in the very numerous Navigational Warning messages That is why there are two different message type letters A and L which actually describe the sam...

Страница 44: ...its special definition of possible message types which have been adjusted for amateur radio usage The existing NAVTEX processor in the PTC II is thus very suitable for fully automatic reception of AM...

Страница 45: ...aves the actual position with the corresponding GPS time The user can call up this position data with the POSition command in the cmd menu The PTC IIex accepts messages in formats GPRMC GPGLL IIRMC an...

Страница 46: ...data throughput What are the reasons then that up until now HF PR works so poorly and apart from forwarding is hardly ever used There is a simple answer The current modulation type for HF PR namely un...

Страница 47: ...to be sent are available 2 If the PTC IIex is the information receiving station IRS the PTC II automatically executes a BREAKIN if the transmission buffer is not empty that means that data for transmi...

Страница 48: ...in the same way as in PR regardless of the actual transmission state of the connected PTCs CHANGEOVER or BREAKIN aren t necessary anymore We want to point out that the selection of the QSO style is a...

Страница 49: ...volume control should be used which enables comfortable loudspeaker operation The very high computing capacity of the PTC IIex is shown to be very advantageous for the Audio processing algorithm In c...

Страница 50: ...this there are special hostmode command which allow the changeover for PACTOR in the hostmode O causes a CHANGEOVER and I causes a BREAKIN Another comfortable way to initiate a CHANGEOVER in the hostm...

Страница 51: ...wever markedly reduced printing errors Higher values 40 60 are recommended for APLINK where data is sent over multiple AMTOR links until the target box is reached and thus a minimum error rate is to b...

Страница 52: ...e unreadable text In an AMTOR QSO instead of using the usual change over sequence it is possible to use the normal PACTOR CHANGEOVER character The PTC changes the PACTOR CHANGEOVER character automatic...

Страница 53: ...compensated switching off this function which is essential for PSK operation is not possible AQrg 1 activates the second additional compensation method The PTC IIex pulls the two carrier frequencies...

Страница 54: ...up the entire PTC mailbox After entering the BAK command the PTC requests a disk file to be opened and waits for the input of a CR which starts the actual back up procedure After the back up is finis...

Страница 55: ...deal value After BAU the PTC answers with BAUDOT RTTY RECEPTION ACTIVE SPEED 45 BD and is ready to receive RTTY transmissions Changing to transmit is done with the CHANGEOVER character set with the CH...

Страница 56: ...or PACTOR and AMTOR The BREAKIN character is a special command for a forced direction change from RX to TX BREAKIN Because this command is used very often the PTC accepts the BREAKIN character only di...

Страница 57: ...tions This increases the Overhead of the box only very slightly as the callsigns are given in small letters and thus lend themselves to efficient Huffman coding If the remote user wants enter a comman...

Страница 58: ...nd let it beep CHOB 0 disables both the sending of the BEL character to the terminal and the beep of the internal buzzer 6 19 CHOchr Default setting 25 Ctrl Y Parameter X 1 127 decimal ASCII code of a...

Страница 59: ...ween 2 and 8 characters Too short arguments are ignored If the callsign is too long it will be truncated at the end If no argument is given the old or the default callsign will be called Connect can b...

Страница 60: ...Firmware are able to accept Robust Connect frames Two PTC II s both running the normal Firmware cannot mutually connect using the Robust Connect since only the Professional Firmware is capable of rece...

Страница 61: ...the time delay caused by the final speed of radio waves DX is only possible with fast transmit receive switching 6 25 CTExt Default setting PTC IIex DSP QUICC System Maildrop QRV Parameter String of 2...

Страница 62: ...RQ connect 2 Audio Only CW identification refer to text 3 Combination of 1 and 2 Automatic CW identification is given after a transmission of approximately 7 minutes and after QRT The CW identificatio...

Страница 63: ...nuously between 40 and 1200 LpM Letters per minute The CW speed applies to the CW ID as well as to the CW terminal 6 30 CWTerm Default setting no Parameter X 40 400 Start receiving speed in LpM The CW...

Страница 64: ...tuning indicator flicker With a correctly adjusted CW signal the traffic LED lights when the CW signal is there and the idle LED when it is not The Audio frequency of the CW terminal is defined by use...

Страница 65: ...ecoded The CW terminal can be closed with the D command or DD may also be used 6 31 CWWeight Default setting 50 Parameter X 5 95 weight of CW characters in This command sets the weighting of the CW ch...

Страница 66: ...24 03 05 Return Or in shortform cmd DA 240305 Return 6 34 DD This command causes an immediate breaking off of the transmission Dirty Disconnect An existing link is not correctly terminated Any text th...

Страница 67: ...TLE 1 RP DL1ZAM 02 MAR 94 17 13 45 1144 New Info 2 RA DK5FH 02 MAR 94 23 30 22 1502 3 NP DL2FAK 03 MAR 94 13 25 15 1362 Mistake 4 NP DL6MAA 03 MAR 94 23 31 46 927 New Software 5 NP DL3FCI 04 MAR 94 20...

Страница 68: ...character is required in order to get a command prompt and input a command Note To ensure proper operation of the PTC IIex s automatic baudrate detection only odd values for the ESCAPE character shou...

Страница 69: ...ell matched antenna please pay particular attention that the chosen frequency is really free Using U 1 Return the Unproto mode 1 is started 100 Bd FSK Now using the FSKAmpl command use the ESCAPE char...

Страница 70: ...37 LFignore 2 activates in addition the multi CR suppression with RTTY and AMTOR FEC reception Multiple CR in a row without other characters between are suppressed except for the first CR In the EOL...

Страница 71: ...in the PTC mailbox The short form L for the LIst command is also accepted by the remote station as in this case no possible confusion with Listen can occur The output format is valid also for the DIR...

Страница 72: ...hieving good monitoring results on PACTOR III the frequency offset should kept lower than 20 Hz Of course an SNR appropriate for the actual speedlevel is necessary for error free reception Nevertheles...

Страница 73: ...ox in AMTOR a user station must first Login using the LOGIn command e g LOGI DL1ZAM The user s callsign is thus made available to the PTC mailbox Only after a correct LOGIn can the AMTOR user station...

Страница 74: ...ust mode during poor channel conditions 2 fast 30 slow Example MAXDown 7 i e the PTC switches down after receiving 7 error packets in a row 6 56 MAXErr Default setting 70 Parameter X 30 255 maximum nu...

Страница 75: ...ng 4 Parameter X 2 30 number of error free packets before up speed Selection of up speed parameter for automatic speed changing MAXUp determines how soon the system steps up under good channel conditi...

Страница 76: ...aves as if the parameter 1 had been chosen The automatic compression used in PACTOR II has proved to be very advantageous and reliable Therefore the MOde parameter should only need to be changed in ex...

Страница 77: ...e is performed if the MYcall command is executed with a valid call as argument in the cmd menu This ensures that after a RESTart or after the first power on all calls are set to a valid value 6 63 MYL...

Страница 78: ...ALL Selected MESSAGE TYPES A Navigational Warning B Meteorological Warning D Search and Rescue Info E Meteorological Forecast L Navigational Warning 2 6 65 1 Activating the NAVTEX Processor The NAVTEX...

Страница 79: ...and cmd NAV AREA ALL Return allows the reception of messages from all areas The command cmd NAV AREA Return without an argument displays the present area codes chosen 6 65 4 Choosing the message laten...

Страница 80: ...de is turned off at which point they become available as usual for NAVTEX reception When the AMTEX configuration is active the AMTEX message types and area codes can be changed as usual e g NAV XYZ or...

Страница 81: ...t Radio listen without entering the pac menu previously cmd PAC M 0 Return 6 69 PDTimer Default setting 12 Parameter X 2 30 PACTOR Duplex BREAKIN time in seconds Defines the PACTOR Duplex BREAKIN time...

Страница 82: ...remote control P command Enter the phase correction data from the reference station as a new initial value for the Phase command inverting the preceding factor i e 78 becomes 78 If a timeout occurs un...

Страница 83: ...PSK output to be increased with the microphone gain control if available The transceiver should be connected either to a dummy load of appropriate power handling capacity or a well matched antenna Ple...

Страница 84: ...QRT character which causes the system to go QRT close the link It can also be sent is the RX mode which then becomes active at the next TX phase In PSK31 RTTY FEC and UNPROTO it switches from transmi...

Страница 85: ...l enabled This command permits the access to the remotablecontrol commands for a distant station With REMote 1 the remote commands are enabled The other station can now use all the commands signified...

Страница 86: ...hilst connected allows the sysop to send a file to the other station All additional information concerning the file File header EOF text path text is suppressed so that for example station description...

Страница 87: ...9 page 54 ESCchr It is also possible to force the PTC IIex to reset its SERBaud value to AUTO As the PTC IIex has no switches to let the user express the intention to reset to AUTO a special procedure...

Страница 88: ...k the measured frequency deviation is additionally given SH could for example show the following Number of RECEIVED packets control blocks TRAFFIC 2 5 REQUEST 0 0 ERROR 0 0 MEMO ARQ 0 0 SLAVE RESPONSE...

Страница 89: ...e or Traffic LED lighting depending on the received RTTY signal Coastal radio stations or other professional RTTY stations normally send the character string ZCZC in advance to a new message The end o...

Страница 90: ...tus information can be implemented The status bytes incl header are sent in direct sequence During the transmission of status information new status requests are ignored The status information is proc...

Страница 91: ...le 6 4 PTC status information Bit 4 6 In STBY condition the PTC IIex analyzes the HF channel and differs between busy and free A busy channel is defined as all signals that are audibly distinctly diff...

Страница 92: ...g 0 Parameter 0 Simple terminal mode 1 Terminal mode with delayed echo 2 Split screen terminal mode 3 Enhanced split screen 4 Split screen with command prompt recognition 5 Split screen also for Packe...

Страница 93: ...R data link status messages monitor information etc is always proceeded with a Ctrl F Only direct answer messages for a command input do not fall under this convention This allows the comfortable admi...

Страница 94: ...channel Setchn as plain text information before the colon Channel numbers of two digits are thus output by two ASCII number characters The prompt information of terminal mode 5 cannot be split I e no...

Страница 95: ...by the TNC command Using this command the PTC IIex up to the desired extend adapts its behaviour to react similar to the WA8DED command interpreter The PTC IIex reacts similar to a normal TNC if the T...

Страница 96: ...s are used for FSK as well as PSK operation With PSK operation care must be taken that the difference between the two tones is exactly 200 Hz to remain compatible with the PT II standard There is noth...

Страница 97: ...c 1 in RTTY and AMTOR With PACTOR the shift direction plays no part in the decoding as the correct relationship is always obtained at the start of the link 3 PACTOR III 1200 1400 Hz Call dial tones fo...

Страница 98: ...ansmission mode for Unproto operation 1 5 Number of packet repetitions This command allows the transmission of broadcasts CQ calls etc in PACTOR without acknowledgment from the receiving station s An...

Страница 99: ...n once a packet is correctly received it will not be received again A data packet may be repeated 3 times but will only appear once at the receiving station s It is recommended that the repetition rat...

Страница 100: ...note that the next character s are figures 6 104 VERIfy This is identical to the RELOad command except the BBS file is NOT loaded into the PTC The checksum is calculated instead so as to check the fil...

Страница 101: ...firmware up to now only for the PTC II without Robust PR 4 PR modem equipment 5A0A example 1 digit Modem type on port 1 0 no modem 1 external foreign modem e g DF9IC modem 2 RMNC KISS interface not su...

Страница 102: ...ailbox operation The filename is the name of the subdirectory in which the message will be stored If this is missing then the PTC reacts with a message missing filename The message can additionally be...

Страница 103: ...is possible Larger or equal 3 reading of all files is possible PR GATE priority Smaller 3 Access to the PR PACTOR gateway is denied Larger or equal 3 Free access to all gates is provided Detailed inf...

Страница 104: ...llegal access to the PR Pactor gateway XUser CALLSIGN Deletes the callsign CALLSIGN from the user list The PTC IIex confirm that with OK The entry ALL cannot not be deleted XUser CALLSIGN xxxx Sets th...

Страница 105: ...g 1400 Parameter X 300 2700 center frequency of the CW filter Sets the center frequency of the CW filter continuously between 300 and 2700 Hz Refer also to command CWfilter chapter 7 3 and the command...

Страница 106: ...Notch Activates the automatic N times notch filter All systematic signals are heavily attenuated The algorithm used leads to considerably less signal distortion of speech signals compared to simpler...

Страница 107: ...ne of 1000 Hz The command can also be used to setup a dual tone generator For this the second frequency is entered after the first one separated by a space Both tones are generated simultaneously whic...

Страница 108: ...7 Audio 94...

Страница 109: ...M FAX and SSTV The FM FSK modulator is phase continuous and highly linear producing an extremely clean transmitted signal The FM FSK demodulated signal is available as a 1 bit square wave at PIN 6 of...

Страница 110: ...standardized at 400 Hz This means that in a normal FAX signal on shortwave the brightness information white is transmitted by a tone of 1900 400 Hz i e 2300 Hz and black is represented by 1900 400 Hz...

Страница 111: ...imes has led to an unnecessary number of different SSTV sub standards some of which are poorly documented A real technical requirement for these multiplicity of standards is not to be found By limitin...

Страница 112: ...ry Both problems are solved with the new modem command JVComm within the fax menu activating a new transmission routine On the receiving side the JVComm modem of the PTC IIex has the same behavior as...

Страница 113: ...nd can be used to terminate a picture 254 Deletes the transmission data buffer and shortens the TX tail to 0 Analysis via data buffer This byte defines the regular end of a picture It must be added to...

Страница 114: ...x can be ended at any time by inputting a byte with the value 255 dec via the RS 232 port It is essential to use the correct baud rate see MBaud command After the ending of Modem operation the PTC IIe...

Страница 115: ...ator demodulator in this case such as BayCom or PCCOM The combination of PTC IIex and TFX emulates a real hostmode TNC for 300 baud Packet that can be operated with a hostmode terminal program such as...

Страница 116: ...appropriately 1500 and 2300 Hz The maximum possible resolution and input filter bandwidth may be pre set using the SResolut parameter Unlike the FM FAX Modem values smaller than 0 measured frequency l...

Страница 117: ...8 bit data width for picture information The practical results however speak against using this method With the JSynch parameter turned on default setting the recognized synchronization pulse is sign...

Страница 118: ...goes to 10 Volts For frequencies lower than 1900 Hz the PTC IIex sets PIN 6 to 10 Volts The NFSK demodulator gives the measured frequency value to the RS 232 interface at a baud rate set by the MBaud...

Страница 119: ...it is AM FAX FM FAX SSTV or FSK the PTC IIex keys the transmitter PTT becomes active when it receives bytes with a value between 0 and 63 The transmitter stays on for exactly 166 7 ms after receiving...

Страница 120: ...parameter or other settings The maximum possible shift of the transmitted FSK signal however is thus limited to 800 Hz In order to generate the synchronization signal below 1500 Hz the PTC IIex must u...

Страница 121: ...solution is as follows 0 1680 pixels sec 1 2500 pixels sec 2 3400 pixels sec 8 9 3 FResolut Default setting 2 Parameter 0 1000 Pixel sec 1 1500 Pixel sec 2 2000 Pixel sec 3 2800 Pixel sec Gives the ma...

Страница 122: ...Hz i e frequencies from 1900 400 Hz to 1900 400 Hz 8 9 7 MBaud Default setting 57600 Parameter X 1200 115200 baudrate during modem operation Sets the baud rate used by the serial interface during MODE...

Страница 123: ...arameter X 0 15 SSTV sub mode Sets the SSTV sub mode required The SMode parameter is only used for the SSTV line synch processing as it is only here that specific information about the various SSTV su...

Страница 124: ...of the RS 232 interface When 10 volts appears the PTT line is activated The PTT line is de activated turned off when the voltage is 10 volts When in the send condition the PTC IIex measures the incom...

Страница 125: ...and 1900 1250 Hz or 750 Hz and 3150 Hz The frequency band for FAX SSTV appears to be shifted about 400 to 500 Hz higher in frequency With normal SSB reception the higher FAX SSTV tones suffer great at...

Страница 126: ...8 FAX 112...

Страница 127: ...expression DAMA is added to the header of the monitored packets if the packet is received by a DAMA Digi The DAMA mode needs not be activated by the user The PTC IIex automatically notices if you are...

Страница 128: ...o 1500 Hz On the receive side the same side band as the transmit side must be used We generally recommend USB With Robust PR modulation selected the PTC assumes that a connection will be via a HF Chan...

Страница 129: ...ter frequency is calculated automaticly from the tone pair set with the TOnes MARk and SPAce commands in the cmd menu 100 Hz are added and subtracted respectively to generate the modem tones This may...

Страница 130: ...pported by many KISS capable systems To switch into the SMACK mode first the normal KISS more needs to be entered KISS master and KISS modem then automatically negotiate if CRC protection SMACK can be...

Страница 131: ...all sign is not set the APRS beacon cannot be activated The MYcall of the virtual channel 0 is automatically set to the Pactor MYcall after a RESTart so that normally only a single MYcall entry is nec...

Страница 132: ...N YYYYY YYW E Allows the entry of the position for the FIX operation Aprs 2 see 9 6 1 The position must be entered exactly in the correct format for Latitude Longitude which means degrees including le...

Страница 133: ...r Home HF If no symbol number is given as an argument the A SY command normal way displays the actual parameter settings however with a current symbol additionally with a short description in square b...

Страница 134: ...d data from the GPS receiver to 1800 seconds 9 6 2 Baud Default setting 1200 Parameter X Baud rate for the radio link Setting checking the radio link baudrate Without a parameter the Baud command show...

Страница 135: ...ter 6 11 page 42 9 6 6 Connect Default setting none Parameter target call Digi1 Digi2 Connect sets up the AX 25 link Connect to DL1ZAM pac C DL1ZAM Return If the link takes place via one or more digip...

Страница 136: ...ect DL1ZAM 8 PTC Mailbox The Command interpreter buffer is 256 characters long Commands plus CTEXT argument should not contain more characters otherwise the CTEXT will be truncated 9 6 11 DIGIpeat Def...

Страница 137: ...h to the hostmode independently 9 6 16 KISS The KISS Mode is activated with the commands KISS or alternatively K out of the normal command mode This usually happens automatically by the KISS PC softwa...

Страница 138: ...given in decimal or hexadecimal prefixed with a character ASCII values Only works in PR terminal mode and can only be accessed in that mode Does not operate in hostmode Filters received and transmit...

Страница 139: ...lp The MText input is done via the normal command interpreter so a convention for the CR character has to be used The CR is represented within the MText string by This would be input like pac MT Welco...

Страница 140: ...CALL and overwrite the SCSPTC with the valid mycall If the MYcall command is executed on the PACTOR side with a valid callsign as an argument the PTC IIex also checks all PR channels for SCSPTC and if...

Страница 141: ...eans that only data addressed to the PTC MYCALL will be accepted by the mailbox This is a legal requirement in many countries as an open BBS may only be operated by especially licensed stations The fu...

Страница 142: ...tting 100 Parameter X 1 30 000 slot time in milliseconds Sets the slot time for the transmitter control The PTC IIex can transmit at particular times only SLottime defines the period between these tim...

Страница 143: ...o Default setting CQ Parameter Call Callsign for Unproto Unproto sets the target callsign for the Unproto operation To start an Unproto transmission just enter the Converse mode with K and everything...

Страница 144: ...tial users would use the normal MYCALL to connect to the PTC IIex If the terminal is off line and the configuration is correct USers 0 or Y0 then all calls irrespective of if they are the normal MYCAL...

Страница 145: ...rove it Especially for new ideas like extended hostmode and AX 25 protocol expansions like as DAMA TheFirmware was and is the basis for development Because of these advantages the wide distribution of...

Страница 146: ...ability of a Packet Radio connection depends on the time parameters Because of this check the initialization files of programs you use in advance and very carefully Often the added examples are design...

Страница 147: ...rminal mode and the hostmode Terminal Mode Hostmode Terminal Mode Hostmode Baud B MCon M CHeck T3 Monitor M CMsg U MStamp K Connect C MYcall I CONStamp K PErsist P CText U RESptime T2 Disconnect D REt...

Страница 148: ...the PTC IIex then queries whether the information has arrived 10 4 4 G G Get is a special Hostmode command and is used to get information about the various Hostmode channels This command is only used...

Страница 149: ...rameter N Monitor switched off I Info frames U Unproto transmissions S Control packets C Monitor also while connected M sets which frame types will be displayed in the monitor 10 4 10 N Default settin...

Страница 150: ...tion command in the cmd menu the output always has NMEA format The NMEA compatible string usually looks like GPGGA 192552 5005 430 N 00845 983 E 1 03 2 7 106 3 M 47 8 M 4F 10 4 15 PT Switches the PTC...

Страница 151: ...ers Limits the number of channels available for remote users Y 5 limits the number of connects from outside to five so if the PTC is presently connected to by 5 stations and a further station attempts...

Страница 152: ...16 If hostmode fax reception is activated 8 bit per sample grey scale FAX data is available on hostmode channel 252 The data field length of the hostmode packets on channel 252 is always 256 The sampl...

Страница 153: ...e byte sequence is usually done automatically by the software as well and may just once be configured correctly in the setup of the program 10 4 24 S If hostmode FAX reception refer to 10 4 22 Page 13...

Страница 154: ...tuning display is activated refer to 9 4on page 115 For 9600 and 19200 baud operation a suitable transceiver is necessary 10 4 28 C This is identical to the CLR command in the main menu of the termin...

Страница 155: ...stmode and is used to define a special extension of the PTC IIex Terminal programs which wish to work with delayed echo in hostmode must logically be appropriately extended to contain this feature and...

Страница 156: ...frequency change is prohibited due to a special actual state of the modem e g when the modem has already detected the beginning of a user access on the PACTOR HF port In principle this problem can alr...

Страница 157: ...led extended hostmode The extended WA8DED Hostmode has established itself as a de facto standard for communication between TNC PTC and PC control programs The extended hostmode makes the polling of th...

Страница 158: ...tes are sent back to the PTC as a response to the G poll The number of bytes calculates as paramater value plus 1 Thus the command G0 is compatible with the usual G poll without argument because it yi...

Страница 159: ...has two basic weak points which can cause serious problems with data corruption or loss during operation 1 There is no reasonable possibility for a resynchronization of the Hostmode operation if throu...

Страница 160: ...esent on the RS 232 interface The character means Binary byte The protocol is based on the extended Hostmode A number of data packets are built up according to this sub protocol The HOST PC is as in W...

Страница 161: ...ses the possibility to quickly inform the Master that the last transmitted packet should be repeated by inserting a short request packet The request packet has the format 170 170 170 85 10 8 3 MASTER...

Страница 162: ...waiting for the MASTER timeout NACK condition Reaction of the SLAVE to the ACK condition Transmission of the present new response packet e g data packet if a G POLL NOTE This packet must be buffered i...

Страница 163: ...m start should have bit 6 set to ensure that a correctly received packet at the SLAVE always leads to an ACK condition This allows the MASTER to start the protocol without having to know the condition...

Страница 164: ...x FOR j 0 TO 7 DO BEGIN IF Odd Data XOR accu THEN accu accu shr 1 XOR 8408 ELSE accu accu shr 1 Data Data shr 1 END crc_table index accu END Build table END Begin InitCRC Expand CRC Table crc ffff Sta...

Страница 165: ...HIGHBYTE 153 When checking the CRC reception one also calculates both the transferred CRC bytes into the CRC value The new CRC value so obtained must equal F0B8 if the block has arrived correctly Alte...

Страница 166: ...parameters are not required and will be ignored if given After turning on the PSK31 terminal the PTC IIex is in the receive condition Various PSK31 relevant settings are at their default or previousl...

Страница 167: ...mpt in terminal mode 5 TERM command has the code cmd 5 or binary 00100101 In the status byte refer to Status command chapter 6 91 page 75 the PTC displays RTTY CW as there are no further free codes av...

Страница 168: ...inverted DQPSK If a DQPSK variant is chosen the PTC IIex signals this with the DQPSK LED Inverted DQPSK is needed when lower sideband is used on an SSB transceiver as here the signal phasors revolve...

Страница 169: ...LED s 1 and 15 flicker The fine tuning can also be carried out with the hot keys Ctrl K and Ctrl L if the VFO does not have a fine enough resolution At first sight the tuning procedure sounds relative...

Страница 170: ...ld show the PTC IIex RAM expansion cmd SYS Ram Return The sys menu commands in detail 12 1 Audio Serves to carry out a so called Audio loop test or check of the analogue I O stages as well as the DSP...

Страница 171: ...SK test routine Return toggles between Mark and Space tones The routine supports the FSK as well as the AFSK outputs The PTT transistor switch is turned on during the FSK test routine The FSK test may...

Страница 172: ...ng bar high tones at the right side If more than 15 tones are used on a speedlevel SL 5 and 6 some tones in the center of the spectrum are omitted With the aid of the tone monitor one can for example...

Страница 173: ...12 SYStest 159...

Страница 174: ...ring a normal firmware update one part of the FLASH is programmed with the new version while the other still contains a part of the old firmware It is very unlikely that such a mixture will run and th...

Страница 175: ...hing the unit OFF again This can also be done with the OFF command of the BIOS refer to 13 3 5 on page 162 At next power on it will start the firmware again Some experience may be necessary to hit the...

Страница 176: ...of the flash selcall By using the FSelcall command it is possible to store your own selcall permanently in FLASH ROM Stores the flash selcall DFCJ cmd FS DFCJ Return Checking the flash selcall cmd FS...

Страница 177: ...and cmd SERB auto Return Switching on the PTC IIex the next time the automatic baud rate recognition will work Without entering arguments the SERBaud command shows the actual baud rate The message aut...

Страница 178: ...component cmd TI 09 56 05 Return or cmd TI 095605 Return 13 3 10 UPDATE Identical to the UPDATE command in the PACTOR firmware This command renews the PACTOR firmware in the Flash ROM of the PTC IIex...

Страница 179: ...o possible to obtain further help on a command whilst in BIOS with Help CMD More details to the RUN command sys Help RUN Return 13 4 6 Led Checks the LED s The PTC IIex tests the whole lighting consol...

Страница 180: ...eed to be changed After switching on the PTC IIex the operation software is expanded from the 8 bit flash loaded in the 32 bit static RAM boot and started The operation software uses the 32 bit data b...

Страница 181: ...00 Hz is allowed The complex modulation scheme often used but very difficult to handle because an adjustment to only a few Hertz was necessary is gone 14 3 The Power supply The PTC IIex contains two p...

Страница 182: ...On the back is the DC input an ON OFF switch an 8 pin DIN socket for the transceiver conection as well as a 9 pin SUB D socket for the terminal connector The construction is largely SMD Every single...

Страница 183: ...14 Circuit Description 169...

Страница 184: ...at and the short packet lengths of AMTOR have been retained These result in a protocol much more resistant to interference than Packet Radio under poor propagation conditions The PACTOR protocol toget...

Страница 185: ...rdware and which can be classed as state of the art The main question was what could be improved in PACTOR I A bit of head scratching provided the answer First of all a significant improvement has to...

Страница 186: ...rporated 15 3 Basics of the PACTOR II protocol 15 3 1 General The PACTOR II protocol PT II is essentially based on the Level I standard consisting of a synchronous half duplex ARQ protocol New however...

Страница 187: ...ximum step speed which finally led to his sampling theory Stemming from his work a special step or impulse waveform was found that contained the ideal characteristics for data transmission over an ele...

Страница 188: ...anges between the steps it s called differential binary phase shift keying DBPSK Every step contains exactly one bit of information If four different phase changes are allowed then the modulation is c...

Страница 189: ...tion AM etc it is NEVER allowed to overdrive the transmitter because intermodulation products will be generated broaden the signal How to adjust the maximum transmitter power will be described in the...

Страница 190: ...e code is called a Viterbi decoder Unfortunately there is an exponential relation ship between constraint length and the computing time required by a Viterbi decoder This is why the use of the Viterbi...

Страница 191: ...makes use of the statistical frequency distribution of characters in plain language text The characters most used e g e and n are coded with only two or three bits Rare characters such as Y can conver...

Страница 192: ...tuned to say 3583 7 kHz or 14079 0 kHz and DL2FAK called providing the frequency is clear If there is PT traffic on the chosen frequency irrespective whether PT I or PT II the PTC IIex will automatic...

Страница 193: ...OR I PACTOR II achieves an effective text throughput of around 3 times that of PACTOR I under average to poor conditions With very weak signals or signals with heavy interference PACTOR II still works...

Страница 194: ...ts As with PACTOR I a CQ call or broadcast is normally carried out with 100 Bd FSK UNPROTO mode see the Unproto command refer to chapter 6 100 page 84 Such transmissions can be read by all PACTOR user...

Страница 195: ...15 Basics 181...

Страница 196: ...e production of the Z80 STI peripherial chip used in the Z80 PTC ended This was then the opportunity to develop the PTCplus Based on an MC68000 processor the PTCplus is the springboard to a totally ne...

Страница 197: ...ACTOR III is the ideal means of fast and reliable data communication over the sometimes difficult medium HF radio The new protocol is fully backwards compatible to existing PACTOR I II networks In sum...

Страница 198: ...or M706 IC 718 Order No 8110 YAESU Audio cable PTC 5 pin DIN to YAESU FT 817 6 pin Mini DIN e g for FT 100 FT 817 FT 897 Also usable for 1k2 Packet Radio Order No 8120 KENWOOD Audio cable PTC 8 pin DI...

Страница 199: ...ies 185 Cable with 5 pin DIN connector Order No 8010 Cable with 8 pin DIN connector Order No 8020 For more accessories and prices please refer to our homapage http www scs ptc com or call for a recent...

Страница 200: ...sh FLASH ROM for easy updates RAM 2 MByte CMOS static Battery Backup Real time clock With battery back up date weekday hrs mins secs System monitoring With an internal processor watchdog Battery 3 V h...

Страница 201: ...B Technical Data 187...

Страница 202: ...C Layout Appendix C 19 Layout B 1 Motherboard Figure B 1 Motherboard 188...

Страница 203: ...C Layout 189...

Страница 204: ...1 The Power Supply V1 LL4004 SI1 500mA L1 47uH L2 47uH X1 DC IN C31 100n V2 LL4004 C10 100n R21 150 C29 100u C30 100n V27 5V1 GND C65 2 2u GND GND 5V P GND GND R71 150 C28 100u GND C68 100n C9 100n GN...

Страница 205: ...2 3 2 1 8 4 U24A TLC272 R74 47K R75 47K R61 47K R78 47K GND GND C22 100u C62 100n C80 100p R62 22K C81 100p L22 C61 1n L21 L28 C64 1n L27 GND GND GND GND GND GND R42 1K R41 10K GND L26 C63 1n L25 GND...

Страница 206: ...R1I 4 R2I 23 R3I 16 T1I 7 T2I 6 T3I 18 T4I 19 T5I 21 R1O 5 R2O 22 R3O 17 V 11 C1 10 C2 13 V 15 C1 12 C2 14 MAX207 U12 C5 100n L4 L5 C33 1n GND L6 L7 C34 1n GND L8 L9 C55 1n GND L10 L11 C56 1n GND L12...

Страница 207: ...Cable 5 9 4 8 3 7 2 6 1 X1 SUB D 9 PIN Molded screws UNC4 40 5 9 4 8 3 7 2 6 1 X2 SUB D 9 SOCKET female screw locks 5 9 4 8 3 7 2 6 1 X3 SUB D 9 PIN female screw locks PTC II e PC GPS Figure C 4 The...

Страница 208: ...computer Pin 3 RxD Receive data input from computer Pin 4 DTR Input RxD secondary serial port Pin 5 Ground GND Pin 6 DSR Output Pin 7 CTS Input Pin 8 RTS Output Pin 9 RI Output TxD secondary serial po...

Страница 209: ...E Connector Pin out D 4 Cable Color Code 8 pol DIN PIN Color PIN Color 1 Violet 5 Blue 2 White 6 Red 3 Yellow 7 Black 4 Green 8 Brown Table D 1 Cable Colors 8 pole DIN cable 196...

Страница 210: ...gain ASCII American Standard Code of Information Interchange 7 bit code for numbers characters special characters and control characters Backup Another word for safety copies which should be done regu...

Страница 211: ...ecause of this the receiver has the possibility to notice and correct transmission errors without transmitting the information again FIR Finite impulse response Digital filter with finite impulse resp...

Страница 212: ...C IIex indicates e g the readiness with cmd TNCs using TheFirmware will display only an asterisk as a prompt Using DOS for example the prompt looks like C DOS PSK Phase Shift Keying RAM Random Access...

Страница 213: ...interface a screen and a keyboard All signals received by the serial interface are displayed on the screen All inputs made at the keyboard are transmitted via the serial interface TTL Transceiver Tran...

Страница 214: ...k In January February 1992 9 ROY PHILPOT DJ0OW PACTOR Here and Now Amateur Radio 12 1992 10 C RICHARDS 9M2CR PACTOR The Magic Successor to RTTY and AMTOR Amateur Radio 3 1993 11 ROY PHILPOT DJ0OW PACT...

Страница 215: ...Index 202...

Страница 216: ...92 158 AUdio 40 Audio functions 35 Audio output level 14 55 69 AUDPerm 158 Auto status in Hostmode 146 B BAKup 40 Bandwidth 92 Baud 122 BAUdot 41 Baudrate 73 165 BC 42 Beep 159 166 Bell 44 BEll 42 BIO...

Страница 217: ...145 F F 136 Fax menu command 101 FAX 54 140 AM FAX 96 102 Comparator 105 FM FAX 97 103 FSK 105 General information 96 LED functions 100 112 Tuning display 112 TX in AM FAX Mode 107 TX in Comparator Mo...

Страница 218: ...t text 47 Directory 52 Enabling for Packet 129 Listing 57 Mail announcement 60 Multiple file operations 24 Packet Radio 25 Packet Radio connect message 123 Passing PR connects to 26 Read command 70 Re...

Страница 219: ...and Status 155 Actication 154 Carrier frequencies 154 General 154 How to start 70 Receiver Tuning 157 CW Identification 157 PSKAmpl 69 PSKTerm 70 PT 70 PTChn 70 PTC II construction 170 Ptt 160 Q Qrt 7...

Страница 220: ...or 94 TOnes 83 TR 84 TRACE 130 Transmission at Modem operation 106 Tuning indicator and behavior 180 TXcomp 111 TXdelay 131 TXDelay 85 TXLevel 131 Typography 2 U U 138 UMlauts 85 Unproto 85 131 Unprot...

Отзывы: