30
CHAPTER 3: CONFIGURATION AND SETUP
087-0067 REV A
SCOTT SAFETY
conform to the National Electric Code, and must comply with all State and local codes
and regulations. Use of incorrect electrical power input may permanently damage the
equipment and could cause serious injury or death to the user.
33339
Table 15
Pre-Operation Checklist - Compressor
ITEM
ACTIVITY FREQUENCY
DETAILS
Maintenance
schedule
Verify
Before each
operation
Verify that the maintenance schedule is up to
date for the unit. Proper routine maintenance
and documentation are the responsibility of the
organization using the equipment. Maintenance
must be performed in accordance with service
guidelines provided by Scott.
Electrical
power source
Check
Before each
operation
Check the electrical power source. Ensure that
the compressor unit is connected to a suitable
electrical power supply, and that there are no
maintenance procedures in process that would
necessitate a Lock Out/Tag Out of the circuit
breaker or master switch.
Air flow
Check
Before each
operation
Make sure there is nothing close to or on top of
the compressor that could interfere with air
flow. For proper operation, the minimum
clearance established at installation on all sides
and above the compressor must be maintained.
Fresh air
supply
Check
Before each
operation
Make sure nothing is operating in the vicinity of
the compressor air intake which might
contaminate the fresh air supply, such as vehicle
exhaust, chimney smoke, ventilator fumes, or
other source of contamination.
High pressure
connections
Check
Before each
operation
Check the high pressure connections. Ensure
that the high pressure outlet(s) are properly
connected to a suitable high pressure air
receiver. If any connection is loose or damaged,
do not start the compressor until all connections
have been properly repaired and thoroughly
inspected.
Oil level
Check
Before each
operation, or
at least once a
week
Check the compressor oil level prior to each
use. To check the oil, remove the oil fill cap and
check the oil level reading. Replenish as
necessary, using only Anderol 500 oil or
XL-700 oil, available from your local Scott
distributor.
Belt
Check
Before each
operation, or
at least once a
week
Check the belt condition and the tension
Loose
components
Check
Before each
operation, or
at least once a
week
Check the compressor for any loose
components
Remote air
intake
Check
Before each
operation, or
at least once a
week
Check the Remote Air Intake for any leaks
Содержание HushAir Connect 7500
Страница 1: ...User Guide 087 0067 Rev A HushAir Connect 7500 COMPRESSOR SYSTEM ...
Страница 2: ......
Страница 3: ...HushAir Connect 7500 User Guide COMPRESSOR SYSTEM 087 0067 Rev A ...
Страница 8: ...IV CONTENTS 087 0067 REV A SCOTT SAFETY ...
Страница 12: ...X LIST OF TABLES 087 0067 REV A SCOTT SAFETY ...
Страница 42: ...20 CHAPTER 2 INSTALLATION 087 0067 REV A SCOTT SAFETY ...
Страница 73: ...Configuring the System 51 SCOTT SAFETY 087 0067 REV A Figure 27 Override Status Screen ...
Страница 106: ...84 CHAPTER 5 MAINTENANCE 087 0067 REV A SCOTT SAFETY Figure 48 Oil Drain Location 3 1 2 ...
Страница 112: ...90 APPENDIX A SPECIFICATIONS 087 0067 REV A SCOTT SAFETY ...
Страница 119: ......
Страница 120: ...Monroe Corporate Center P O Box 569 Monroe NC 28111 Telephone 800 247 7257 FAX 704 291 8330 Web www scottsafety com ...