78
CHAPTER 5: MAINTENANCE
087-0067 REV A
SCOTT SAFETY
Remove Air
Intake Inspection
X**
X**
X**
X**
Storage
Inspection/Drain
and Recharge
X
Run Compressor
(60Mins), 2 Min
Cool Down
X
Wiring and
Cables
(Inspection)
X****
X
X
X
Bleeder Value
Service (Charge
Station)
AR
Door Detent
Lubrication
(Change Station)
AR
Nipple Seal
Replacement
(Charge Station)
AR
* Note: See manufacture instruction for your type of sample kit.
** Note: Performed at 50 hours initially, adjust for operating conditions.
*** Note: Basic design hours only, replacement time frame is determined by air
sampling & Dew Point Monitor.
**** Note: The first 90 days inspection and service requires the assistance of a Scott
Certified Technician.
***** Note: Use only Anderol 500 oil or XL-700 oil, available from your local Scott
distributor.
AR= As Required.
Table 27
Recommended Maintenance Schedule - Users (continued)
ITEM
WEEKLY*
90 DAY
50 HOUR
200 HOURS
OR
ANNUALLY
500 HOURS
OR
ANNUALLY
Содержание HushAir Connect 7500
Страница 1: ...User Guide 087 0067 Rev A HushAir Connect 7500 COMPRESSOR SYSTEM ...
Страница 2: ......
Страница 3: ...HushAir Connect 7500 User Guide COMPRESSOR SYSTEM 087 0067 Rev A ...
Страница 8: ...IV CONTENTS 087 0067 REV A SCOTT SAFETY ...
Страница 12: ...X LIST OF TABLES 087 0067 REV A SCOTT SAFETY ...
Страница 42: ...20 CHAPTER 2 INSTALLATION 087 0067 REV A SCOTT SAFETY ...
Страница 73: ...Configuring the System 51 SCOTT SAFETY 087 0067 REV A Figure 27 Override Status Screen ...
Страница 106: ...84 CHAPTER 5 MAINTENANCE 087 0067 REV A SCOTT SAFETY Figure 48 Oil Drain Location 3 1 2 ...
Страница 112: ...90 APPENDIX A SPECIFICATIONS 087 0067 REV A SCOTT SAFETY ...
Страница 119: ......
Страница 120: ...Monroe Corporate Center P O Box 569 Monroe NC 28111 Telephone 800 247 7257 FAX 704 291 8330 Web www scottsafety com ...