Maintaining the Compressor
79
SCOTT SAFETY
087-0067 REV A
Draining the
Condensate Container
This section covers draining the condensate container.
If operating the compressor for an extended period of time, be aware of the level of
condensate in the condensate container. The container should be drained when it is
approximately three-quarters (3/4) full. See
Compressor condensate contains lubricating oil and/or substances which must be
disposed of in accordance with local, State, and Federal laws and regulations.
1
If the compressor is running, press the Stop key on the control panel to stop the
compressor.
2
Remove the container from under the compressor frame and pour condensate out
from the hose connection spout.
3
Dispose of condensate according to hazardous waste regulations.
Table 28
Recommended Maintenance Matrix - Users
ITEM
ACTIVITY/
SYMPTOM
FREQUENCY
DETAILS
Compressor
Operate
Weekly
Run the compressor for a period of not
less than one hour allowing for at least
four condensate drain cycles. This
prohibits moisture build up in the unit
and provides proper lubrication.
Nuts, Screws,
Fittings
Inspect
Weekly
Inspect all nuts, screws, and fittings for
tightness.
Condensate
Container
Drain
Periodic
Electrical Fuses
Replace
Fuses/
Inoperative
motor
As needed
Motor Saver
Reset
As needed
“Resetting the Motor Saver” on
High Pressure
Reset
As needed
“Resetting the High Pressure” on
Inlet Filter
Check
Periodic
“Checking the Inlet Filter” on
Purification
Filters
Check
Periodic
Drive Belt
Check
Periodic
Oil Level
Check
Daily
Check the compressor’s oil level.
Moisture in Oil
Check
Daily
Check for no moisture (emulsification)
in oil.
Oil or Air Leaks
Check
Daily
Check and if found, these leaks must be
rectified immediately.
Oil
Change
See
Содержание HushAir Connect 7500
Страница 1: ...User Guide 087 0067 Rev A HushAir Connect 7500 COMPRESSOR SYSTEM ...
Страница 2: ......
Страница 3: ...HushAir Connect 7500 User Guide COMPRESSOR SYSTEM 087 0067 Rev A ...
Страница 8: ...IV CONTENTS 087 0067 REV A SCOTT SAFETY ...
Страница 12: ...X LIST OF TABLES 087 0067 REV A SCOTT SAFETY ...
Страница 42: ...20 CHAPTER 2 INSTALLATION 087 0067 REV A SCOTT SAFETY ...
Страница 73: ...Configuring the System 51 SCOTT SAFETY 087 0067 REV A Figure 27 Override Status Screen ...
Страница 106: ...84 CHAPTER 5 MAINTENANCE 087 0067 REV A SCOTT SAFETY Figure 48 Oil Drain Location 3 1 2 ...
Страница 112: ...90 APPENDIX A SPECIFICATIONS 087 0067 REV A SCOTT SAFETY ...
Страница 119: ......
Страница 120: ...Monroe Corporate Center P O Box 569 Monroe NC 28111 Telephone 800 247 7257 FAX 704 291 8330 Web www scottsafety com ...