Use and Operation
Once started, the ice machine will automatically
make ice until the bin is full of ice. When ice level
drops, the ice machine will resume making ice.
There are four indicator lights at the front of the
control box that provide information on the
condition of the machine.
I
ndicator Lights:
•
Power
•
Status
•
Water
•
De-scale & Sanitize
Indicator Lights & Their Meanings
Power
Status
Water
De-Scale & Sanitize
Steady Green
Normal
Normal – bin full or making ice
-
-
Blinking Green
Self Test
Failure
Switching on or off
-
-
Blinking Red
-
Diagnostic shutdown or, if making
ice, temperature sensor failure
Lack of
water
-
Yellow
-
-
-
Time to de-scale and
sanitize
Blinking
Yellow
-
-
-
In Cleaning mode
Light off
No power
Switched off
Normal
Normal
All Blinking
Unit remotely locked out – check with leasing company
If the Water light is on, the machine has sensed a
lack of water. Check the water supply to the
machine. The water could have been shut off or the
water filter cartridges might need to be changed.
If the De-Scale light is on, the machine has
determined that it needs to be cleaned. Contact an
authorized Scotsman service agent and have the
machine cleaned, de-scaled and sanitized.
May 2008
Page 11
CU1526, CU2026, CU3030
Service Manual
Note: Water cooled models, the refrigeration
system discharge pressure is factory set at 245
PSIG, which should yield a freeze cycle discharge
water temperature of about 105-110 degrees F.
Adjust if necessary.
Manual
Harvest
Clean
Code
Display
Component Operation Indicator Lights
Code
Description
. . . . . . . . . . Freeze Cycle
flashes . . . . Freeze Cycle is Pending
. . . . . . . . . . Harvest Cycle
flashes . . . . Manual Harvest
. . . . . . . . . . Bin is Full
. . . . . . . . . . Clean Cycle
. . . . . . . . . . Board Locked
. . . . . . . . . . Test Mode
. . . . . . . . . . Off
. . . . . . . . . . Self Test Failed
flashes. . . . Max Freeze - Retrying
. . . . . . . . . . . Max Freeze Time Shut Down
flashes . . . . Max Harvest - Retrying
. . . . . . . . . . Max Harvest Time Shut Down
. . . . . . . . . . Slow Water Fill
. . . . . . . . . . High Discharge Temp
. . . . . . . . . . Sump Temp Sensor Failure
. . . . . . . . . . Discharge Temp Sensor Failure
flashes . . . Short Freeze - Retrying
Short Freeze - Thin ice
- Unit Remotely
Locked Out - Contact Leasing Company
F
F
H
H
b
C
L
d
O
E
1
1
2
2
3
4
5
7
8
8 . . . . . . . . . . . .
All 4 Upper Lights Flashing
Control Operation - See Manual
Water Light On
De-Scale Light On
Flush Setting
Test Mode
Recall Diagnostic Codes
Reset from Code 1, 2, 4 or 8
- Restore water supply to
machine.
- Clean and sanitize
machine.
- To Change: Depress Off
for 3 seconds. Press On to select purge
(1-5) setting or A for Automatic.
- Depress Off for 3 seconds,
then depress Clean for 3 seconds.
- Depress Off
for 3 seconds. Press Harvest repeatedly
to go from most recent to oldest of 10.
- Depress
Off then Depress On.
Technician Section
02-4302-01
On
Off
Power
Status
De-scale
Water
Sanitize