1.
Locate ice thickness sensor. Squeeze
mounting legs together to release sensor.
Wash the metal surfaces of the sensor and the
adjustment screw with ice machine scale
remover solution. Also wash the water
distributor and curtain with the ice machine
cleaner solution.
2.
Locate water sensor. Squeeze catches
together and pull up to remove sensor. Wash
metal surfaces of sensor with ice machine
scale remover solution.
3.
Mix a solution of sanitizer.
Note: A possible sanitizing solution may be made
by mixing 1 ounce of liquid household bleach with 2
gallons of warm (95-115
o
F.) potable water.
4.
Thoroughly wash all surfaces of the ice
thickness sensor, water level sensor, curtain
inside of the top panel and the water distributor
with the sanitizer solution.
5.
Wash all interior surfaces of the freezing
compartment, including storage bin liner with
the sanitizer solution.
6.
Return water level sensor, ice thickness
sensor, water distributor and curtain to their
normal positions.
7.
Push and hold the clean button to drain the
reservoir. Push and release the clean button
again and when the purge valve indicator light
goes out, immediately pour the remaining
cleaning solution into the reservoir.
8.
Circulate the sanitizer solution for 10 minutes,
then push and release the Clean button.
9.
Allow the water system to be flushed of
sanitizer for at least 20 minutes, then push and
release the Off button.
10. Push and release the On button to resume ice
making.
11. Return the top panel and front louvered panel
to their normal position and secure with the
original fasteners.
Air cooled condenser filter
1. Remove left front grill .
2. Wash the dust and grease off the filter.
3. Return it to its original position.
Do not operate the machine without the filter in
place except during cleaning.
Air cooled condenser
If the machine has been operated without a filter
the air cooled condenser fins will need to be
cleaned.
They are located under the fan blades. The
services of a refrigeration technician will be
required to clean the condenser.
Exterior Panels
Fingerprints, dust and grease build up on the
panels will require occasional cleaning.
Water filters
If the machine has been connected to water filters,
check the cartridges for the date they were
replaced or for the pressure on the gauge. Change
cartridges if they’ve been installed more than 6
months or if the pressure drops too much when the
ice machine fills with water.
November 2011
Page 33
CU1526, CU2026, CU3030
Service Manual
Inspect Orifice Holes
Inspect Water Distributor