May 2008
Page 56
CU1526, CU2026, CU3030
Service Manual
Removal and Replacement
Water Pump
CU1526 or CU2026
1.
Top access and top panel removal is required for this procedure.
2.
Disconnect electrical power.
3.
Shut water supply Off.
4.
Remove top panel.
5.
Remove two screws holding reservoir to evaporator support bracket. Lower sump at front.
6.
Reach in sump and remove water pump discharge hose.
7.
Reach from top, rotate water pump CCW until it is in the release position, then pull the pump up and
out.
CU3030
1.
Disconnect electrical power.
2.
Disconnect electrical connection from pump
motor.
3.
Remove discharge hose from pump
4.
Rotate water pump CCW until it is in the release position, then pull the pump up and out.
Electrical Shock
Hazard
.
Disconnect electrical
power before
beginning removal
procedure.
Electrical Shock
Hazard
.
Disconnect electrical
power before
beginning removal
procedure.