Technical Information
Pressure Control Information
Cut In (PSIG)
Cut Out (PSIG
Fan Pressure Control
240
190
High Pressure Cut Out AC
390
500
High Pressure Cut Out WC
300
400
September 2010
Page 41
CU1526, CU2026, CU3030
Service Manual
Compressor Amp Draws
Voltage
Brand
Base Model
Freeze
Harvest
CU1526
115
Copeland
ASB14C3E-IAA-302
5 - 5.5
5.6 - 5.9
230/50
Copeland
ASB14C3E-IAZ-202
CU2026
115
Copeland
ASE24C3E-IAA-302
5.4 - 5.9
6.1 - 6.3
230/60
Copeland
ASE24C3E-IAV-202
230/50
Copeland
ASE24C3E-IAZ-202
CU3030
115
Tecumseh
AKA9438ZXA
6 - 7.3
7.2 - 7.9
230/60
Tecumseh
AKA9438ZXD
230/50
Tecumseh
AKA9438ZXC
Refrigerant Charge
Model
Charge, R-404A, Oz
CU1526A
12
CU1526W
9
CU2026A
15
CU2026W
9
CU3030A
12
CU3030W
12
Superheat
•
CU1526 - 20
o
F
•
CU2026 - 16
o
F falling during freeze to ~8
•
CU3030 - 15
o
F falling during freeze to ~8
BTUH
•
CU1526 - 2700 CU2026 - 3700 CU3030 - 4300