Removal and Replacement
Water Reservoir
CU1526 or CU2026
1.
Top access and top panel removal is required for this procedure.
2.
Shut water supply OFF.
3.
Remove left grill.
4.
Push and hold the Off button until the unit stops.
5.
Push and hold the Clean button until a - appears in the code display. The pump will drain the
reservoir.
6.
Disconnect electrical power.
7.
Remove top panel.
8.
Remove two screws holding reservoir to evaporator support bracket. Lower sump to drain water.
9.
Reach in sump and remove water pump discharge hose.
10. Reach from top, rotate water pump CCW until it is in the release position, then pull the pump up and
out.
11. Pull up on the water pump / float bracket. It is not necessary to remove the bracket, but it must be
raised about an inch to allow the back wall of the reservoir to clear the float shield.
12. Pull water reservoir forward and down into the bin.
Note: The reservoir has tabs that go thru the back panel. You may have to lift up and pull forward to
release them.
May 2008
Page 53
CU1526, CU2026, CU3030
Service Manual
Electrical Shock
Hazard
.
Disconnect electrical
power before
beginning removal
procedure.