Polyester band
Cardboard box
Forklift insertion
side
Wooden skid
Forklift insertion
side
Less than 150 mm
Less than
150 mm
Ventilation
300 mm
or more
500 mm
or more
300 mm
or more
800 mm
or more
Transportation / Carriage / Movement
Warning
1. This product is heavy. Pay attention to safety and
the position of the product when it is transported,
carried, and moved.
2. Read the Operation Manual carefully before moving
the product after unpacking.
Caution
1. Never put the product down on its side as this may
cause a failure.
The product will be delivered in the packaging shown below.
<When packaged>
Model
Weight [kg]
Dimensions [mm]
HRLE090-A-20/40
176
Height 1320 x Width 580 x Depth 1240
HRLE090-W-20/40
170
2. Transporting with forklift
1. A licensed driver should drive the forklift.
2. Insert the fork to the place specified on the label. The fork
should reach through to the other side of the product.
3. Be careful not to bump the fork to the cover panel or piping
ports.
3. Transporting with casters
1. This product is heavy and should be moved by at least two
people to avoid falling.
2. Do not grip the piping port on the back side or the handles
of the panel.
3. Do not pass over bumps, etc., with the casters.
Caution
If this product is to be transported after delivery, please
use the original packaging the product was delivered
in. If other packaging is to be used, carefully package
the product so as to prevent the product from incurring
any damage during transport.
Installation
Warning
1. Do not place heavy objects on top of this product,
or step on it.
The external panel can be deformed and danger can result.
Caution
1. Install on a rigid floor which can withstand this prod-
uct's weight.
2. Refer to the Operation Manual for this product, and
secure an installation space that is necessary for
the maintenance and ventilation.
<Air-cooled refrigeration>
1. The air-cooled type product exhausts heat using the fan that is
mounted to the product. If the product is operated with insuffi-
cient ventilation, ambient temperature may exceed 45°C, and
this will affect the performance and life of the product. To prevent
this ensure that suitable ventilation is available (see below).
2. For installation indoors, ventilation ports and a ventilation
fan should be equipped as needed.
3. If it is impossible to exhaust heat from the installation area in-
doors, or when the installation area is conditioned, provide a
duct for heat exhaustion to the air outlet port of this product
for ventilation. Do not mount the inlet of the duct (flange) di-
rectly to the air vent of the product, and keep a space larger
than the diameter of the duct. Additionally, consider the resist-
ance of the duct when making the air vent port for the duct.
<Heat radiation amount / Required ventilation rate>
Model
Heat
radiation
amount
[kW]
Required ventilation rate [m
3
/min]
Differential temp. of 3
°
C
between inside and outside
of installation area
Differential temp. of 6
°
C
between inside and outside
of installation area
HRLE090-A-20/40
Approx.18
305
155
Be sure to read this before handling the products. Refer to the back cover for safety instructions.
For temperature control equipment precautions, refer to the “Handling Precautions for SMC
Products” and the “Operation Manual” on the SMC website: https://www.smcworld.com
HRLE
Series
Specific Product Precautions 2
27