Maintenance
58
05.00|EVG 55|en
Cleaning
Gripper
The module corresponds to IP code 20.
• Clean the module dry, remove all coarse dirt and chips from the
cavities of the module.
• Check for damage and, if necessary, replace the module.
Any repair work on the module may only be carried out by SCHUNK.
Controller
The module corresponds to IP code 20.
• Clean the module dry, remove all coarse dirt and chips from the
cavities of the module.
• Check for damage and, if necessary, replace the module.
Lubricants/lubrication points
SCHUNK recommends the lubricants listed.
During maintenance, treat all greased areas with lubricant. Thinly ap-
ply lubricant with a lint-free cloth.
Lubrication point
Lubricant
Metallic sliding surfaces
THK AFC-Grease
The lubricant quantity depends on the stroke lengths and stroke cy-
cles.
Lubrication point „S“
1
Profile rail
2
Profile carriage
3
Gripper base jaw
7.3
7.3.1
7.3.2
7.4