Assembly and installation
05.01|EVG 55|en
27
Assembly and installation
Mechanical connection
WARNING
Risk of injury from uncontrolled movements!
If the energy supply is switched on or residual energy remains in the
system, parts may move unexpectedly and cause serious injuries.
• Switch off energy supply.
• Make sure there is no residual energy in the system
The values apply to the whole mounting surface to which the product
is mounted .
Requirements for levelness of the mounting surface (Dimensions in mm)
Diameter
Permissible unevenness
< 100
< 0.02
> 100
< 0.05
• Use suitable connecting elements (adapter plate) to connect the
module to the machine/system.
• Observe the permissible screw-in depth.
5
5.1
Levelness of the
mounting surface