Maintenance
7 Maintenance
WARNING
Risk of injury due to unexpected movements!
If the power supply is switched on or residual energy remains in
the system, components can move unexpectedly and cause
serious injuries.
•
Before starting any work on the product: Switch off the power
supply and secure against restarting.
•
Make sure, that no residual energy remains in the system.
7.1 Maintenance intervals
Interval
(million cycles)
for EGS 25 - 40
Maintenance work
1000 cycles
or once per day
Travel an entire stroke.
2
Treat all grease areas with
lubricant,
2
Clean all parts thoroughly, check for damage
and wear
20
as required
Changing sensor bracket,
For extreme ambient and application conditions, shortened
maintenance cycles can ensure the lifespan is maintained.
CAUTION
Material damage due to hardening lubricants!
Lubricants harden more quickly at temperatures above 60°C,
leading to possible product damage.
•
Reduce the lubricant intervals accordingly.
45