NOTE
If a sensor bracket (8) is in the way when sliding a swivel stop (5)
or a swivel stop (5) is in the way when sliding a sensor bracket (8),
the order of these parts in the circular groove can be changed.
To do this, the associated T-nuts are removed from the groove
and placed back in. For removing and placing back in, the circular
groove has an expansion between 285°-330°.
If the basic setting of the product is not to be used, switching lugs
must be mounted before calibration or swivel stops and sensor
brackets changed,
.
Proceed as follows during configuration:
1. If necessary, change swivel stops and sensor brackets.
2. Adjust angle of rotation
3. Installing and configuring the sensor
4. Adjusting the sensor
5. Adjusting the slider
Adjust angle of rotation
To adjust the angle of rotation, the swivel end positions are
adjusted using the swivel stops (5). The swivel stops (5) are fixed
with screws (1) in the circular groove.
1. Loosen screws (1) until the swivel stop (5) can be slid into the
groove.
2. Align product to the first swivel position and slide the swivel
stop (5) up to the pointer stop (9).
3. Tighten screw (1), in order to fix the swivel stop (5).
Tightening torque: 0.68 Nm at EGS 25, 1.2 Nm at EGS 40
4. Proceed identically with the second swivel stop in the second
swivel position.
Installing and configuring the sensor
The sensors are fixed in the sensor bracket (8) with the screws (2).
1. Loosen screw (2) until the slide (7) can be moved axially with
the sensor.
2. Slide sensor into the slide (7) until it is flush with the top edge
of the slide (7).
Distance to switching lug: approx. 0.5 mm
3. Tighten screw (2).
Tightening torque: 0.08 Nm at EGS 25, 0.1 Nm at EGS 40