background image

 

8

 

USING THE ENGINE START FEATURE

Your battery charger can be used to jump 

start your car if the battery is low. Follow 

all safety instructions and precautions for 

charging your battery. Wear complete eye 

protection and protective clothing. 

WARNING:

 Using the ENGINE START 

feature WITHOUT a battery installed in 

the vehicle could cause damage to the 

vehicle’s electrical system. 

NOTE:

 If you have charged the battery 

and it still will not start your car, do not 

use the Engine Start feature, or it could 

damage the vehicle’s electrical system. 

Have the battery checked.

1. 

With the charger unplugged from the 

AC outlet, connect the charger to the 

battery following the instructions given 

in 

Charging a Battery in the Vehicle

.

2. 

Plug the charger AC power cord into 

the AC outlet.

3. 

With the charger plugged in and 

connected to the battery and chassis, 

press the RATE SELECTION button 

until the ENGINE START LED is lit. 

4. 

Crank the engine until it starts or 5 

seconds pass. If the engine does not 

start, wait 3 minutes before cranking 

again. This allows the charger and 

battery to cool down.

NOTE: 

During extremely cold weather, or 

if the battery is under 2 volts, boost the 

battery for 5 minutes before cranking the 

engine.

5. 

If the engine fails to start, use the 30A 

Boost rate for 5 more minutes before 

attempting to crank the engine again.

6. 

After the engine starts, unplug the AC 

power cord before disconnecting the 

battery clamps from the vehicle.

7. 

Clean and store the charger in a dry 

location.

NOTE:

 If the engine does turn over but 

never starts, there is not a problem with 

the starting system; there is a problem 

somewhere else with the vehicle. STOP 

cranking the engine until the other problem 

has been diagnosed and corrected.

ENGINE STARTING NOTES

During the starting sequence listed above, 

the charger is set to one of three states:

• Wait for cranking –

 The charger waits 

until the engine is actually being cranked 

before delivering the amps for engine start 

and will reset if the engine is not cranked 

within 15 minutes. (If the charger resets, it 

sets itself to the default start up settings). 

While waiting for cranking, the digital 

display shows 

rdy

.

• Cranking – 

When cranking is detected, 

the charger will automatically deliver up 

to its maximum output as required by 

the starting system for up to 5 seconds 

or until the engine cranking stops. The 

digital display shows a countdown of the 

remaining crank time. 

• Cool Down –

 After cranking, the charger 

enters a mandatory 3 minute (180 second) 

cool down state. The digital display 

indicates the remaining cool down time in 

seconds. It starts at 180 and counts down 

to 0. After 3 minutes, the digital display will 

change from displaying the countdown to 

displaying 

rdy

. The CHARGING LED 

 

will then be lit.

USING THE BATTERY VOLTAGE 

TESTER 

1. 

With the charger unplugged from the 

AC outlet, connect the charger to the 

battery, following the instructions given 

in previous sections.

2. 

Plug the charger AC power cord into 

the AC outlet.

3. 

Press the BATTERY TYPE button until 

the correct type is indicated.

4. 

Read the voltage on the digital display. 

Keep in mind that this reading is only a 

battery voltage reading; a false surface 

charge may mislead you. Compare the 

reading to the following chart.

6V Battery 

Voltage Reading

12V Battery 

Voltage Reading

Battery 

Condition

6.4 or more

12.8 or more

Charged

6.1 to 6.3

12.2 to 12.7

Needs charging

Less than 6.1

Less than 12.2

Discharged

TESTER AND CHARGER 

When first turned on, the unit operates 

only as a tester, not as a charger. 

Selecting a charge rate activates the 

battery charger and deactivates the tester. 

Pressing the RATE SELECTION button 

when the ENGINE START LED is lit 

(except during the 180 second cool 

down) will shut off the charger and 

activate the tester.

POWER-UP IDLE TIME LIMIT

If no button is pressed within 10 minutes 

after the battery charger is first powered 

up, the charger will automatically switch 

from tester to charger if a battery is 

connected. In that case, the charger will 

be set to the Charging/Maintaining rate 

and gel cell battery type.

Содержание XC85-CA

Страница 1: ...USE This manual will explain how to use the battery charger safely and effectively Please read and follow these instructions and precautions carefully POR FAVOR CONSERVE ESTE MANUAL DEL USUARIO Y LEA...

Страница 2: ...11 LIMITED WARRANTY 11 WARRANTY CARD 23 CONTENIDOS INSTRUCCIONES IMPORTANTES DE SEGURIDAD 12 PRECAUCIONES DE SEGURIDAD PERSONAL 12 PREPARACI N PARA LA CARGA 13 UBICACI N DEL CARGADOR 13 PRECAUCIONES...

Страница 3: ...E INSTRUCTIONS EACH TIME YOU USE THE CHARGER b To reduce risk of battery explosion follow these instructions and those published by battery manufacturer and manufacturer of any equipment you intend to...

Страница 4: ...position and removing AC cord from electric outlet Never allow clips to touch each other 5 2 Attach clips to battery and chassis as indicated in sections 6 and 7 6 FOLLOW THESE STEPS WHEN BATTERY IS I...

Страница 5: ...States is not recommended and should not be used 8 3 USING AN EXTENSION CORD The use of an extension cord is not recommended If you must use an extension cord follow these guidelines Pins on plug of...

Страница 6: ...e to be suspended in close proximity with the plate s active material In theory this enhances both the discharge and recharge efficiency The AGM batteries are a variant of Sealed VRLA valve regulated...

Страница 7: ...ntain mode of operation MAINTAIN MODE FLOAT MODE MONITORING When the CHARGED MAINTAINING green LED is lit the charger has started maintain mode In this mode the charger keeps the battery fully charged...

Страница 8: ...livering the amps for engine start and will reset if the engine is not cranked within 15 minutes If the charger resets it sets itself to the default start up settings While waiting for cranking the di...

Страница 9: ...when storing the charger This will help prevent accidental damage to the cords and charger Store the charger unplugged from the AC power outlet in an upright position Store inside in a cool dry place...

Страница 10: ...eptacle The charger may be overheated Battery may be severely discharged Crank time varies with the amount of current drawn If cranking draws more than the Engine Start Rate crank time may be less tha...

Страница 11: ...its authorized representatives in order for repair or replacement to occur Manufacturer does not provide any warranty for any accessories used with this product that are not manufactured by Schumacher...

Страница 12: ...cargador del tomacorriente antes de intentar llevar a cabo cualquier actividad de mantenimiento o limpieza El simple apagado de los controles no reducir este riesgo 1 11 ADVERTENCIA RIESGO DE GASES EX...

Страница 13: ...la bater a alcance el nivel especificado por el fabricante de la bater a No provoque derrames En lo que concierne a bater as que no cuentan con tapas extra bles para pilas tales como bater as de plom...

Страница 14: ...loque motor 6 7 Al desconectar el cargador apague todos los interruptores en su caso desconecte el cable de C A retire el gancho del chasis del veh culo y luego retire el gancho del terminal perteneci...

Страница 15: ...rograme en el modo de carga la car tula cambiar autom ticamente a On encendido para mostrar que la carga ha comenzado y despu s mostrar el porcentaje de carga obtenido por la bater a y asi indicado 6...

Страница 16: ...este tipo de c lulas son m s bajos que los de los otros estilos de la bater a de plomo cido sta es probablemente la c lula m s sensible en t rminos de las reacciones adversas a la carga de sobretensi...

Страница 17: ...la bater a totalmente cargada mediante una peque a corriente cuando corresponda Si el cargador tiene que funcionar al m ximo en corriente continua de mantenimiento a un periodo de 12 horas se translad...

Страница 18: ...e figura anteriormente el cargador se configura en uno de estos tres estados Esperar para dar arranque El cargador espera hasta que se le de arranque al motor antes de suministrarle amperes para que a...

Страница 19: ...a lectura es menor a los 13 4 voltios o m s de 14 6 volts consulte el manual de su veh culo o pida que el sistema de carga sea supervisado por un t cnico calificado 12 MANTENIMIENTO Y CUIDADO Con cuid...

Страница 20: ...orriente de CA fuera de funcionamiento Conexi n el ctrica deficiente Controle la posible presencia de fusibles abiertos o disyuntores que suministren energ a al tomacorriente de CA Revise el cable de...

Страница 21: ...nte Salida 6V CC 2A continua 12V CC 2A 6A 120 seg 2A 60 seg 6A 6V 12V CC 12A 30A 120 seg 12A 60 seg 30A 85A intermitente 5 seg en 180 seg off 15 ANTES DE DEVOLVER A REPARACIONES Si estas soluciones no...

Страница 22: ...que nos sean el Fabricante o si esta unidad es revendida a trav s de un vendedor minorista no autorizado El Fabricante no realiza ninguna otra garant a incluidas a t tulo enunciativo las garant as ex...

Страница 23: ...e Purchased____________________ Date of Purchase__________ Store Location_____________________ UPC Number_________________________ Serial Number_______________________________________ SEE PRODUCT For...

Отзывы: