background image

 

6

 

RATE SELECTION BUTTON

Use this button to select one of the following:

• 6<>2A CHARGE/MAINTAIN – 

For 

charging small and large batteries. Not 

recommended for industrial applications.

• 30A BOOST –

 For quickly adding 

energy to a severely discharged or large 

capacity battery prior to Engine Start. 

The unit will automatically switch to 

6<>2A Charge/Maintain after the 30A 

Boost operation has completed.

• 85A ENGINE START –

 Provides 

additional amps for cranking an engine 

with a weak or run-down battery. Always 

use in combination with a battery.

NOTE:

 Once the charger has started 

charging the battery; if you press the Rate 

Selection button once, the output current is 

shut off and the display will show 

OFF

 and 

then the battery voltage. If you press the 

Rate Selection button again, the current 

will go back on at the same setting it was 

when it was turned off. 

LED INDICATORS

 

REVERSED (red) LED flashing: 

The 

connections are reversed.

 

CHARGING (yellow/orange) LED 

lit:

 The charger is charging the battery.

 

CHARGING (yellow/orange) LED 

flashing:

 The charger is in abort mode.

 

CHARGED/MAINTAINING (green) 

LED pulsing:

 The battery is fully charged 

and the charger is in maintain mode.

NOTE:

 See 

Operating Instructions

 for a 

complete description of the charger modes.

BATTERY TYPE BUTTON 

Use this button to set the type of battery  

to charge.

• 

 

 Used in cars, trucks and 

motorcycles, these batteries have vent caps 

and are often marked “low maintenance” or 

“maintenance-free”. This type of battery is 

designed to deliver quick bursts of energy 

(such as starting engines) and has a 

greater plate count. The plates are thinner 

and have somewhat different material 

composition. Regular batteries should not 

be used for deep-cycle applications.

• 

 

 The Absorbed Glass Mat 

construction allows the electrolyte to be 

suspended in close proximity with the 

plate’s active material. In theory, this 

enhances both the discharge and recharge 

efficiency. The AGM batteries are a variant 

of Sealed VRLA (valve regulated lead-acid) 

batteries. Popular uses include high-

performance engine starting, power sports, 

deep-cycle, solar and storage batteries.

• 

 

 The electrolyte in a GEL cell has 

a silica additive that causes it to set up 

or stiffen. The recharge voltages on this 

type of cell are lower than those for other 

styles of lead-acid battery. This is probably 

the most sensitive cell in terms of adverse 

reactions to overvoltage charging. Gel 

batteries are best used in VERY DEEP 

cycle application and may last a bit longer 

in hot weather applications. If the wrong 

battery charger is used on a gel cell 

battery, poor performance and premature 

failure will result.

11. OPERATING INSTRUCTIONS

WARNING:

 A spark near the battery may 

cause an explosion. 

NOTE:

 This charger is equipped with 

an auto-start feature. Current will not be 

supplied to the battery clamps until a 

battery is properly connected. The clamps 

will not spark if touched together. 

CHARGING A BATTERY  

IN THE VEHICLE

1. 

Turn off all the vehicle’s accessories.

2. 

Keep the hood open.

3. 

Clean the battery terminals.

4. 

Place the charger on a dry, non-

flammable surface.

5. 

Lay the AC/DC cables away from any  

fan blades, belts, pulleys and other 

moving parts.

6. 

Connect the battery, following the 

precautions listed in sections 6 and 7. 

7. 

Connect the charger to an electrical 

outlet.

8. 

Select the battery type and desired rate.

9. 

When charging is complete, 

disconnect the charger from the AC 

power, remove the clamps from the 

vehicle’s chassis, and then remove 

the clamp from the battery terminal.

CHARGING A BATTERY OUTSIDE  

OF THE VEHICLE

1. 

Place battery in a well-ventilated area.

2. 

Clean the battery terminals.

3. 

Connect the battery, following the 

precautions listed in sections 6 and 7. 

4. 

Connect the charger to the electrical 

outlet.

Содержание XC85-CA

Страница 1: ...USE This manual will explain how to use the battery charger safely and effectively Please read and follow these instructions and precautions carefully POR FAVOR CONSERVE ESTE MANUAL DEL USUARIO Y LEA...

Страница 2: ...11 LIMITED WARRANTY 11 WARRANTY CARD 23 CONTENIDOS INSTRUCCIONES IMPORTANTES DE SEGURIDAD 12 PRECAUCIONES DE SEGURIDAD PERSONAL 12 PREPARACI N PARA LA CARGA 13 UBICACI N DEL CARGADOR 13 PRECAUCIONES...

Страница 3: ...E INSTRUCTIONS EACH TIME YOU USE THE CHARGER b To reduce risk of battery explosion follow these instructions and those published by battery manufacturer and manufacturer of any equipment you intend to...

Страница 4: ...position and removing AC cord from electric outlet Never allow clips to touch each other 5 2 Attach clips to battery and chassis as indicated in sections 6 and 7 6 FOLLOW THESE STEPS WHEN BATTERY IS I...

Страница 5: ...States is not recommended and should not be used 8 3 USING AN EXTENSION CORD The use of an extension cord is not recommended If you must use an extension cord follow these guidelines Pins on plug of...

Страница 6: ...e to be suspended in close proximity with the plate s active material In theory this enhances both the discharge and recharge efficiency The AGM batteries are a variant of Sealed VRLA valve regulated...

Страница 7: ...ntain mode of operation MAINTAIN MODE FLOAT MODE MONITORING When the CHARGED MAINTAINING green LED is lit the charger has started maintain mode In this mode the charger keeps the battery fully charged...

Страница 8: ...livering the amps for engine start and will reset if the engine is not cranked within 15 minutes If the charger resets it sets itself to the default start up settings While waiting for cranking the di...

Страница 9: ...when storing the charger This will help prevent accidental damage to the cords and charger Store the charger unplugged from the AC power outlet in an upright position Store inside in a cool dry place...

Страница 10: ...eptacle The charger may be overheated Battery may be severely discharged Crank time varies with the amount of current drawn If cranking draws more than the Engine Start Rate crank time may be less tha...

Страница 11: ...its authorized representatives in order for repair or replacement to occur Manufacturer does not provide any warranty for any accessories used with this product that are not manufactured by Schumacher...

Страница 12: ...cargador del tomacorriente antes de intentar llevar a cabo cualquier actividad de mantenimiento o limpieza El simple apagado de los controles no reducir este riesgo 1 11 ADVERTENCIA RIESGO DE GASES EX...

Страница 13: ...la bater a alcance el nivel especificado por el fabricante de la bater a No provoque derrames En lo que concierne a bater as que no cuentan con tapas extra bles para pilas tales como bater as de plom...

Страница 14: ...loque motor 6 7 Al desconectar el cargador apague todos los interruptores en su caso desconecte el cable de C A retire el gancho del chasis del veh culo y luego retire el gancho del terminal perteneci...

Страница 15: ...rograme en el modo de carga la car tula cambiar autom ticamente a On encendido para mostrar que la carga ha comenzado y despu s mostrar el porcentaje de carga obtenido por la bater a y asi indicado 6...

Страница 16: ...este tipo de c lulas son m s bajos que los de los otros estilos de la bater a de plomo cido sta es probablemente la c lula m s sensible en t rminos de las reacciones adversas a la carga de sobretensi...

Страница 17: ...la bater a totalmente cargada mediante una peque a corriente cuando corresponda Si el cargador tiene que funcionar al m ximo en corriente continua de mantenimiento a un periodo de 12 horas se translad...

Страница 18: ...e figura anteriormente el cargador se configura en uno de estos tres estados Esperar para dar arranque El cargador espera hasta que se le de arranque al motor antes de suministrarle amperes para que a...

Страница 19: ...a lectura es menor a los 13 4 voltios o m s de 14 6 volts consulte el manual de su veh culo o pida que el sistema de carga sea supervisado por un t cnico calificado 12 MANTENIMIENTO Y CUIDADO Con cuid...

Страница 20: ...orriente de CA fuera de funcionamiento Conexi n el ctrica deficiente Controle la posible presencia de fusibles abiertos o disyuntores que suministren energ a al tomacorriente de CA Revise el cable de...

Страница 21: ...nte Salida 6V CC 2A continua 12V CC 2A 6A 120 seg 2A 60 seg 6A 6V 12V CC 12A 30A 120 seg 12A 60 seg 30A 85A intermitente 5 seg en 180 seg off 15 ANTES DE DEVOLVER A REPARACIONES Si estas soluciones no...

Страница 22: ...que nos sean el Fabricante o si esta unidad es revendida a trav s de un vendedor minorista no autorizado El Fabricante no realiza ninguna otra garant a incluidas a t tulo enunciativo las garant as ex...

Страница 23: ...e Purchased____________________ Date of Purchase__________ Store Location_____________________ UPC Number_________________________ Serial Number_______________________________________ SEE PRODUCT For...

Отзывы: