5 Data Input
SCHMIDT
®
PressControl 3000 – V1.3
23
No. Parameter
Description
25 idle-stroke monitoring
This parameter defines whether the “idle-stroke monitoring” function is active or not (0=active,
1=inactive)
26
max.force idle-stroke
If the “idle-stroke monitoring” function is active, this parameter defines the maximum allowed force
which must not be reached.
27
stroke for idle-stroke
If the “idle-stroke monitoring” function is active, this parameter defines the stroke which has be
controlled.
30 PC on/off
This parameter defines whether the control unit has to be connected to an external PC for
operation.
31
SPC on/off
This parameter determines whether the "SPC " has been switched on or not (0=off, 1=on).
40
Move tolerance on/off
This parameter defines whether the “Offset of tolerance data” function is active or not (0=active,
1=inactive)
41
Ref-pos. stroketol.1
This parameter defines the intersection of the reference curve with the stroke tolerance 1.
42
Force tare on/off
The "Force tare" function is used to tare the force value after each stroke to the value "0".
45
Part check on/off
This parameter defines whether a part is available on an optionally mounted workpiece fixture or
not (0=active, 1=inactive)
47 ACK n.ok-box on/off
This parameter defines whether a part has fallen into an optionally mounted reject box or not
(0=active, 1=inactive).
50
Bend up [mm/kN]
The measured bending constant eliminates the elastic properties of the overall system.
51
BDC signal (I1.3) exist.
This parameter defines whether the press is provided with a cylinder switch or not (0=not provided,
1=provided)
52
TDC signal (I1.4) exist.
dto
54
Sensor type
Enter the sensor type (5 kN, 20 kN, 100 kN or 160 kN) according to the activated press type.
55
Adm offsetdrift pos.
The allowed offset drift is set by default to 50 increments. If the value of the force measuring
system exceeds the nominal value or drops below it by 50 increments when the control unit is
switched on, the error message “Error force measuring system” appears on the display. This error
message indicates a possible defect of the force measuring system (e. g. sensor deformed). The
force measuring system should be immediately checked and calibrated again!
56
Adm offsetdrift neg.
dto.
57
Aq. distance PDA force
The “increment” of the process data acquisition determines the frequency of the written measuring
points (standard value 5 inc., i.e., every 5 increments one measuring point). The larger the value,
the fewer measuring points are written.
58
Aq. distance PDA stroke
dto.
59
Offset stroke
The “Offset stroke” value is machine specific. The measured value for the activated machine is
included in the test certificate.