10 Quality monitoring
SCHMIDT
®
PressControl 3000 – V1.3
44
Select the "Output Diagram" parameter.
Press the "Enter" key. The parameter is set with the value "Continuous".
By pressing the "Enter" key again, you can reset the parameter to "Single".
By default, when the curve output is called, the force/stroke diagram of the
pressing process is displayed.
Alternatively, you can have the press curves displayed in a force/time or
stroke/time diagram. This allows individual process sequences to be
visualized, which can then be used for optimizing further pressing
processes.
Select the "Diagram" parameter.
Select the desired diagram type by pressing the "Enter" key several
times.
By default, the diagram is displayed in the metric system of units (mm/kN).
Select the "Units" parameter.
Press the "Enter" key. The parameter is assigned the value
"Imperial/US". Now the diagram will be displayed in the units "lbs" and
"inch".
By pressing the "Enter" key again, you can reset the parameter to "Metric".
Enlarging details
To make detailed examinations, you have the possibility to enlarge individual
details of the curve (zoom functions). These settings are made in the "Zoom
diagram" menu.
Select the "Curve Output" system function key.
Press the "Enter" key.
Select the "Zoom Functions" command.
1
CtrON
CtrOFF
...
...
Servic
Zoom Diagram
Zoom +
Zoom -
Zoom Fit
Zoom All
Figure 10-3: "Zoom Diagram" menu
Diagram type
System of units