10 Quality monitoring
SCHMIDT
®
PressControl 3000 – V1.3
50
Select the "Data Input" system function key.
Select the "Move tolerance on/off" parameter.
Enter the value "0"
Record the data of a reference curve.
Determine the target passage in a stroke tolerance. This value can be
read in the “Desired range str.tol1” line of the Data Output 2.
Select the "Data Input" system function key.
Select the "Desired range str.tol1" parameter.
Enter the value for the target passage.
Select the "Data Input" system function key.
Select the "Move tolerance on/off" parameter.
Enter the value "1". To switch the function off again, enter the value "0".
With the function switched on, the tolerance windows will be offset in each
press process automatically by the difference of the actual and target
passages in the reference curve of stroke tolerance 1. This offset is
displayed in the curve window.
2.00
1.50
1.00
.500
0.0
F[kN]
s[mm]
16.51
20.18
23.85
27.50
WA1
F1
-.8806
Demo 1
Figure 10-11: Force curve with offset of the tolerance data
Switching on/off
the offset