11 Maintenance and servicing
SCHMIDT
®
PressControl 3000 – V1.3
51
11 Maintenance and servicing
Safety instructions
The control unit may only be installed and serviced by setup engineers
who have been commissioned and trained by the company.
Any work on the electrical equipment of the press must be carried out
only by trained electricians or by specially instructed persons under the
control and supervision of a trained electrician and in accordance with
the applicable electrical engineering rules and regulations.
All spare parts must comply with the technical requirements established
by SCHMIDT Technology. This is always guaranteed in the case of
original spare parts.
11.1 Setting the force offset
Each force sensor has a different output signal in the unloaded state.
However, this output signal must be in a defined range. The force offset
allows you to adjust the output signal.
Switch the control unit on.
Select the "Data Output" system function key.
Press the "Data Output" system function key again. Now the current
process data of the sensors and the evaluation of the monitoring
windows will be displayed.
The “Offset force” parameter will show the currently set force offset.
Servic
...
...
CtrOFF
CtrON
1
.000 mm
Desired range str.tol2
.000 mm
Desired range str.tol1
0 N
Average force wind.F4
0 N
Average force wind.F3
0 N
Average force wind.F2
0 N
Average force wind.F1
19 inc
Offset force
112 inc
Increment stroke
0 inc
Increment force
1.030 mm
Stroke
0 N
Force
Dataset 1
( )
2
Figure 11-1: View of “Output 2”
The force offset can be set at the amplifier board via a potentiometer.
Set the force offset to a value of about “50”. To increase the force
offset, turn the screw on the potentiometer to the left. To decrease the
force offset, turn the screw on the potentiometer to the right.
CAUTION
!
Switch on control
Setting the force offset