39
17.10.2016 12:29
DTX-Series 1000 cN
Unit cN
Material: CU 0.25-0.4mm
Material: CU 0.25-0.4mm
Material: CU 0.25-0.4mm
Start: 11:38:09 17.10.16
Start: 11:39:10 17.10.16
Start: 11:40:12 17.10.16
Stop: 11:38:17 17.10.16
Stop: 11:39:18 17.10.16
Stop: 11:40:20 17.10.16
Last: 237
Last: 221
Last: 239
Avg: 236
Avg: 234
Avg: 235
Max: 246
Max: 243
Max: 245
Min: 216
Min: 217
Min: 214
std.dev.: 125
std.dev.: 115
std.dev.: 120
MAXPeak: 570
MAXPeak: 544
MAXPeak: 564
MINPeak: 40
MINPeak: 44
MINPeak: 40
HI-Alarm: 850
HI-Alarm: 850
HI-Alarm: 850
Lo-Alarm: 150
Lo-Alarm: 150
Lo-Alarm: 150
Records: 8000
Records: 8000
Records: 8000
374
229
385
410
206
382
438
190
399
461
189
410
478
215
430
489
278
454
497
355
466
498
415
466
492
441
467
3.7.4.3 Displaying the saved measured values on a PC
The SCHMIDT software
Tension-Inspect 3
is supplied with the tension meter. It
allows you to easily and accurately analyze the saved measured values and export
them to an Excel table.
Sample memory printout
3.7.3.4 Deleting the saved measured values
If data is saved in the tension meter, the display shows “Mem” and indicates the free
memory space.
Deleting data:
- Press the „Recall“ and buttons
- Then press the
button and confirm with the
button.
This clears the memory.