7
Model
Tension Range
cN
Textile Industry
Applications
Wire Industry
Applications
(Copper Wire)
DTX-200
0.2 - 200.0
max. 200 tex
max. 0.15 mm Ø
DTX-500
0.5 - 500.0
max. 500 tex
0.05 - 0.25 mm Ø
DTX-1000
10 - 1000
max. 1000 tex
0.10 - 0.40 mm Ø
DTX-2000
20 - 2000
max. 2000 tex
0.30 - 0.60 mm Ø
DTX-2500
25 - 2500
max. 2500 tex
0.30 - 0.60 mm Ø
DTX-4000
40 - 4000
max. 4000 tex
0.35 - 0.80 mm Ø
DTX-5000
50 - 5000
max. 5000 tex
0.40 - 1.00 mm Ø
DTX-10K
0.1 - 10.00 daN
max. 10000 tex
0.70 - 1.20 mm Ø
DTX-20K
0.2 - 20.00 daN
max. 20000 tex
1.00 - 1.70 mm Ø
DTX-30K
0.3 - 30.00 daN
max. 30000 tex
1.20 - 2.00 mm Ø
DTX-50K
0.5 - 50.00 daN
max. 50000 tex
1.40 - 2.00 mm Ø
DTX-60K-V1
0.6 - 60.00 daN
max. 60000 tex
1.80 - 3.00 mm Ø
2 Available models
Calibration:
According SCHMIDT factory procedure
Accuracy:
For PA from 5 % up to 100 % full scale:
± 0.5 % full scale ± 1 digit
remaining tension range and other calibration materials:
± 3 % FS* ± 1 digit
Memory for material
2 for SCHMIDT calibration plus 9 for customized calibrations
curves:
Measuring units:
Force (switchable): cN, daN, g, kg, N, lb
Thickness (switchable): mm, inch
Overrange:
Approx. 10 % full scale, full scale, without accuracy guarantee
Overload protection:
100 % full scale
Measuring principle:
Strain gauge bridge
Measuring roller
Max. 0.2 mm
deflection:
Signal processing:
digital
Measuring frequency:
Max. 1 kHz (1000 measuements/sec.), internal 8 kHz
Display:
Graphic LCD display
3 different displays: numeric, numeric with bargraph,
X-Y-diagramm (time-tension)
Display update time:
2/sec (Display update)
Memory:
MIN, MAX, PEAK, AVG and LAST.
60.000 values at 255 measuring periods
Memory modes:
4 Memory modes with statistical evaluation
Damping:
Adjustable electronic damping (averaging)
Cal. Adjustment:
±
10 steps in 1 % increments
Thickness compensation:
Max. 2.5 mm (not available for all models)
Output signal:
USB
Auto power off:
Approx. 3 minutes of non-use
2.1 Specifications