15
3.4 Tension meter settings
Thumbpiece positions
Pos. 1
Pos. 2
Pos. 0
2 = Measurement position
0 = Adjustment position
1 = Threading position (guide rollers in their forward position)
fig. 3.4
Menu settings can be changed with the thumbpiece in Pos. 0 (Adjustment
position). To perform measurements the thumbpiece must be in the measure-
ment position (2).
Tension meter settings
- Press the
and
buttons simultaneously to access the main menu.
- The and buttons can be used to select the various menu items of the main menu,
the submenus and the settings menus.
- Press the button to open the selected menu; by pressing the or
button you can
close the menu without saving changes.
- In menus with multi-digit fields (e.g. date) use the and buttons to move forward
and backward between digits.
- Press the
button to save the settings and exit the settings menu or press the
button to exit the current menu without saving.
- To exit the main menu press the
button.