Operating Manual
VacuMaster
Chapter 2
Technical Data
J. Schmalz GmbH
Aacher Straße 29
D - 72293 Glatten
Tel +49 +7443 / 2403 - 0
Fax +49 +7443 / 2403 - 259
http://www.schmalz.de
e-mail: [email protected]
BA 30.30.01.00197
Status 03.2013 / Index 00
Page 7 / 18
2 Technical Data
Vacuum generated with electric pump
Type of pump EVE
8 D
25 D
Voltage
230 / 400 V
400 V
Mains frequency [Hz]
50 / 60
Motor power [kW]
0,35
0,9
Suction capacity [m³/h]
8
25
Fuse protection (recommended) [A]
10
16
Temperature range
+5 °C to +40 °C
Noise level (DIN 45 635) [dB(A)]
61
65
For more technical information about the pump,
see Operating Manual “Vacuum Pump“.
Permissible load on the suspension bolt or shackle [kg]
VM 1000 VM 2000
1500
2500
2.1 Permissible Loads
VM 1000 VM 2000
1000 kg
2000 kg
The maximum permissible load is specified for a vacuum of -0,6 bar and with all suction pads in contact with the
workpiece.
On devices which can be swivelled, a coefficient of friction between the suction pad and the workpiece of µ=0.5 is
assumed (if necessary, check the actual coefficient of friction!).