![Schmalz SXMPi Скачать руководство пользователя страница 50](http://html1.mh-extra.com/html/schmalz/sxmpi/sxmpi_operating-instructions-manual_1212905050.webp)
Installation
50 / 66
EN-US · 30.30.01.01721 · 01 · 09/19
9.3.1 Connecting the Compressed Air and Vacuum
How to Perform Pneumatic Connection for Ejector Variant H
2
1
1
Compressed air connection
2
Vacuum connection
The compressed air connection G3/8" is marked with the number 1 on the ejector.
4
Connect compressed air hose. The max. tightening torque is 6 Nm.
The vacuum connection G3/8" is marked with the number 2 on the ejector.
4
Connect vacuum hose. The max. tightening torque is 6 Nm.
How to Perform Pneumatic Connection for Ejector Variant Q
Compressed air
Vacuum
4
The pneumatic connection is performed by connecting the ejector plug to the Quick Change
adapter.
Содержание SXMPi
Страница 1: ...SXMPi IO Link Class B Operating Instructions WWW SCHMALZ COM EN US 30 30 01 01721 01 09 19...
Страница 53: ...Installation EN US 30 30 01 01721 01 09 19 53 66 1 When using a Schmalz connection cable see Accessories...