Product Description
12 / 66
EN-US · 30.30.01.01721 · 01 · 09/19
3.4 Ejector Structure
7
1
2
3
5
10
11
13
12
6
8
9
14
16
17
15
4
1
G3/8" vacuum connection in H version (la-
bel: 2 [V])
2
Power blow-off module
3
Valve screw for blow-off volume flow
4
Manual auxiliary actuation for pilot valves
5
“Suction” pilot valve – NO, NC or IMP (de-
pending on version)
(IMP variant without manual auxiliary ac-
tuation)
6
“Blow-off” pilot valve – NC
7
Condition monitoring
8
Operating and display elements
9
Type plate
10
M12-5 electrical connection
11
Silencer
12
Mounting holes (2x Ø 5.5 mm)
13
G3/8" compressed air connection in H ver-
sion (label: 1 [P])
14
Horizontal pneumatic connection (H)
(1[P]= G3/8", 2[V]= G3/8")
15
2x M5 mounting threads
16
Quick Change module (Q)
17
Accessories: Quick change double block++
+