Description of Functions
EN-US · 30.30.01.01721 · 01 · 09/19
39 / 66
7.14 Displaying the Software Version [0x0017]
The software version indicates the software currently running on the internal controller.
The system firmware can be updated using the “Firmware Update” profile defined by IO-Link. If neces-
sary, this will also update the firmware for the valve module. The PD bit In Byte 1.2 signals when a more
recent version is available in the supply module.
7.15 Displaying the Serial Number [0x0015]
The serial number indicates the production period of the ejector.
ü
Open the system menu.
1. Use the
or
button to select the parameter [
5nr
].
2. Confirm using the
button.
ð
The first three decimal places of the serial number will be displayed (the digits x10
6
). The decimal
point at the far left lights up. This corresponds to the three-digit block with the highest per-
ceived value.
3. Use the
and
buttons to display the remaining decimal places of the serial number.
The decimal points show which three-digit block of the serial number is shown in the display.
The serial number consists of 3 number blocks:
Displayed section
10
6
10
3
10
0
Digit block
0.48
61.8
593.
The current serial number in this example is 48 618 593.
4
To exit the function, press the
button.
7.16 Displaying the Part Number [0x00FA]
The part number both appears on the label on the ejector, and is stored electronically.
ü
Open the system menu.
1. Use the
or
button to select the part number parameter [
Art
].
2. Confirm using the
button.
ð
The first two digits of the part number are displayed.
3. The remaining digits of the part number are displayed with the
button. The displayed decimal
points are part of the part number.
The part number consists of 4 number blocks with a total of 11 digits.
Displayed section
1
2
3
4
Digit block
10.
02.0
2.00
383
The part number in this example is 10.02.02.00383.
4
To exit the function, press the
button.
7.17 Production setup profiles
In IO-Link mode, the ejector can store up to four different production setup profiles (P-0 to P-3). All im-
portant parameter data for workpiece handling is stored in these profiles. The profile is selected by means
of the process data byte PDO byte 0. Thus parameters can be adjusted to suit differing process conditions.