Description of Functions
36 / 66
EN-US · 30.30.01.01721 · 01 · 09/19
4. Use the
or
button to enter the first digit of the PIN code
5. Confirm using the
button.
6. Enter the remaining digits in the same way.
7. Press the
button to save the PIN code.
ð
The menus are now locked.
The PIN code “000” must be set for permanent deactivation of the lock.
Full access to the device is still possible via IO-Link even if a PIN is enabled. The current PIN can also be
read out and changed/deleted (PIN = 000) via IO-Link.
7.11.2 Unlocking the Menus
Menus can be protected against unauthorized access by defining a PIN code [
Pin
] in the configuration
menu. When the lock is active, [
Loc
] flashes in the display or the PIN code is requested.
Tips and Tricks for Parameter Setting
•
By pressing the
or
button for approx. 3 seconds, the value to be changed is
scrolled through quickly
•
If you exit the modified value by briefly pressing
, the value will remain unchanged.
The menus can be unlocked as follows:
1. Press the
button.
2. Use the
or
button to enter the first digit of the PIN code
3. Confirm using the
button.
4. Enter the remaining digits in the same way.
5. Press the
button to unlock the menu.
ð
When a valid PIN is entered, the message [
VnC
] is displayed.
ð
When an invalid PIN is entered, the message [
Loc
] is displayed and the menus remain locked.
The lock is automatically activated once more when the selected menu is closed or the desired function
has been completed. The PIN code 000 must be set for permanent deactivation of the lock.
The PIN is set to 000 on delivery. The menus are not protected.
If you cannot remember the correct PIN code, read or reset the PIN code from the IO-Link, or
use NFC to reset to factory settings.
7.11.3 Restricting Access Using Device Access Locks [0x000C]
In IO-Link mode, the "Device Access Locks" default parameter is available to prevent changes to parame-
ter values using the operating element of the ejector.
A menu lock using the Device access locks parameter has a higher priority than the menu PIN. In other
words, this lock cannot be bypassed by entering a PIN, and remains in place.
It can only be canceled using IO-Link, not on the ejector itself.