Operating and Menu Concepts
24 / 66
EN-US · 30.30.01.01721 · 01 · 09/19
Display
code
Parameter
Possible settings
Explanation
uni
Vacuum unit
bAr
P5i
iXG
k
PA
Define the displayed vacuum unit
Vacuum in mbar
Vacuum in psi
Vacuum in inHg
Vacuum in kPa
dPY
Display rota-
tion
5td
Red
Display configuration
Standard
rotated 180°
Eco
Display in ECO
mode
oFF
Lo
on
Configure the display
ECO mode is deactivated – the display remains on
The brightness is reduced by 50 percent.
Eco mode activated – if no buttons are pressed, the
display turns off after one minute
P1n
PIN code
Value from
001
to
999
Specify the PIN code, lock the menus
If the PIN code is
000
, then the device is not
locked.
nFC
NFC lock
ON
D15
LoC
NFC lock:
NFC active
Completely switched off
Write-protected
rE5
Reset
YE5
All parameter values are reset to factory settings.
The factory settings for the parameters are listed under
(> See ch. Factory Settings, Page 17)
in the Techni-
cal Data section.
5.3.2 Changing the Parameters of the Configuration Menu
1. Press the
button for at least three seconds.
ð
The display will flash [-C-] during this process.
2. Use the
or
button to select the desired parameter.
3. Confirm using the
button.
4. Use the
or
button to change the value.
5. If the menu is locked: Enter a valid PIN code.
6. Press the
button to save the modified value.
7. To exit the configuration menu, press the
button.
Tips and Tricks for Parameter Setting
•
By pressing the
or
button for approx. 3 seconds, the value to be changed is
scrolled through quickly
•
If you exit the modified value by briefly pressing
, the value will remain unchanged.