10.2 Error messages
If an error occurs, it is reported/shown on the display.
The following table shows all the error codes:
Code dis-
played
Explanation
E03
Zero-point adjustment of the vacuum sensor outside ± 3% FS
E07
Supply voltage is too low
E17
Supply voltage is too high
FFF
Present vacuum exceeds the measurement range
-FF
Overpressure in vacuum circuit; this normally happens exclusively in blow off mode.
t-1
The measured evacuation time t1 exceeds the specified value, the display alternately
shows t-1 and the vacuum level.
-L-
The leakage L is greater than the set value -L-, the display will alternately show -L- and
the vacuum level.