Technical Data
EN-US · 30.30.01.01963 · 01 · 09/21
15 / 52
H3
H4
H5
H6
d1
d2
d5
d3
d4
B1
7.5
30
7.5
17.5
Dependent on the particular
mini compact ejector; see
chapter 3.1 “Product Name”
9
4.3
12.5
All specifications are in mm
4.4.3 Maximum Torque
Connection
Max. torque
Mounting hole d4
1 Nm
Electrical connector G3
Hand-tight
4.4.4 Factory Settings
Code
Parameter
Value of the factory setting
5P1
Switching point SP1
750 mbar
rP1
Reset point rP1
600 mbar
5P2
Switching point SP2
550 mbar
rP2
Reset point rP2
540 mbar
tbL
Blow off time
0 s
ctr
Control
Activated =
on
t-1
Evacuation time
0 s
-L-
Leakage value
0 mbar/s
uni
Vacuum unit
Vacuum unit in mbar =
bar
4.4.5 Pneumatic circuit plans
Legend:
NC
Normally closed
NO
Normally open
1
Compressed air connection
2
Vacuum connection
3
Exhaust outlet
1A
Compressed air connector for separate blow-
off
Содержание 10.02.02.05588
Страница 1: ...Mini Compact Ejector SCPMc Operating Instructions WWW SCHMALZ COM EN US 30 30 01 01963 01 09 21 ...
Страница 16: ...Technical Data 16 52 EN US 30 30 01 01963 01 09 21 NC NO NC EB NO EB ...
Страница 51: ...30 30 01 01963 01 10 21 51 52 ...
Страница 52: ... J Schmalz GmbH EN US 30 30 01 01963 01 09 21 Subject to technical changes without notice ...