Installation
EN-US · 30.30.01.01963 · 01 · 09/21
35 / 52
CAUTION
Noise pollution due to incorrect installation of the pressure and vacuum connec-
tions
Hearing damage
4
Correct installation.
4
Wear ear protectors.
8.3.1 Connecting the Compressed Air and Vacuum
Description of the Pneumatic Connector
1
2
1
Compressed air connector (marking 1)
2
Vacuum connection (marking 2)
The (threaded or push-in) compressed air connector is marked with the number 1 on the mini compact
ejector.
4
Connect the compressed air hose. For threaded connectors, the maximum tightening torque is 1 Nm.
The (threaded or push-in) vacuum connector is marked with the number 2 on the mini compact ejector.
4
Connect the vacuum hose. For threaded connectors, the maximum tightening torque is 1 Nm.
8.3.2 Instructions for the Pneumatic Connection
To ensure problem-free operation and a long service life for the mini compact ejector, only use ade-
quately maintained compressed air and take the following requirements into account:
•
Use air or neutral gas in accordance with EN 983, filtered to 5 μm, unoiled.
•
Dirt particles or foreign bodies in the connections, hoses or pipelines may lead to partial or complete
mini compact ejector malfunctions.
•
Shorten the hoses and pipelines as much as possible.
•
Keep hose lines free of bends and crimps.
•
Use only pipes or hoses with the recommended inner diameter to connect the mini compact ejector:
Содержание 10.02.02.05588
Страница 1: ...Mini Compact Ejector SCPMc Operating Instructions WWW SCHMALZ COM EN US 30 30 01 01963 01 09 21 ...
Страница 16: ...Technical Data 16 52 EN US 30 30 01 01963 01 09 21 NC NO NC EB NO EB ...
Страница 51: ...30 30 01 01963 01 10 21 51 52 ...
Страница 52: ... J Schmalz GmbH EN US 30 30 01 01963 01 09 21 Subject to technical changes without notice ...