Operation
EN-US · 30.30.01.01963 · 01 · 09/21
39 / 52
9 Operation
9.1 General Preparations
WARNING
Extraction of hazardous media, liquids or bulk material
Personal injury or damage to property!
4
Do not extract harmful media such as dust, oil mists, vapors, aerosols etc.
4
Do not extract aggressive gases or media such as acids, acid fumes, bases, biocides, dis-
infectants or detergents.
4
Do not extract liquids or bulk materials, e.g. granulates.
Always carry out the following tasks before activating the system:
1. Before each start of operations, check that the safety features are in perfect condition.
2. Check the product for visible damage and deal with any problems immediately (or notify the super-
visor).
3. Ensure that only authorized personnel are present in the working area of the machine or system and
that no other personnel are put in danger by switching on the machine.
During automatic operation, there must be no people in the system danger area.
9.2 Changing the Blow-Off Flow Rate on the Ejector
Do not overwind past the stop on the valve screw. The blow off flow rate can be adjusted
within the range between 0% and 100%.
Valve screw
+
–
The figure shows the position of the valve screw for adjusting the blow off volume throw. The valve screw
is equipped with a stop on both sides.
•
Turn the valve screw clockwise to reduce the flow rate.
•
Turn the valve screw counterclockwise to increase the flow rate.
Содержание 10.02.02.05588
Страница 1: ...Mini Compact Ejector SCPMc Operating Instructions WWW SCHMALZ COM EN US 30 30 01 01963 01 09 21 ...
Страница 16: ...Technical Data 16 52 EN US 30 30 01 01963 01 09 21 NC NO NC EB NO EB ...
Страница 51: ...30 30 01 01963 01 10 21 51 52 ...
Страница 52: ... J Schmalz GmbH EN US 30 30 01 01963 01 09 21 Subject to technical changes without notice ...