Storage
Store the device and its accessories in a dark, dry and
frost-proof place that is inaccessible to children. The
optimum storage temperature is between 5 and 30˚C.
Store the electrical tool in its original packaging.
Cover the electrical tool in order to protect it from dust
and moisture.
Store the operating manual with the electrical tool.
Electrical connection
The electrical motor installed is connected and
ready for operation. The connection complies with
the applicable VDE and DIN provisions.
The customer‘s mains connection as well as the
extension cable used must also comply with these
regulations.
• The product meets the requirements of
EN 61000-3-11 and is subject to special connection
conditions. This means that use of the product at any
freely selectable connection point is not allowed.
• Given unfavorable conditions in the power supply the
product can cause the voltage to fluctuate temporarily.
• The product is exclusively intended for use at con-
nection points that have a continuous current-carrying
capacity of at least 100 A per phase.
• As the user, you are required to ensure, in consultati-
on with your electric power company if necessary, that
the connection point at which you wish to operate the
product meets the specified requirements.
Important information
In the event of an overloading the motor will switch
itself off. After a cool-down period (time varies) the mo-
tor can be switched back on again.
Damaged electrical connection cable
The insulation on electrical connection cables is often
damaged.
This may have the following causes:
•
Passage points, where connection cables are
passed through windows or doors.
•
Kinks where the connection cable has been improp-
erly fastened or routed.
•
Places where the connection cables have been cut
due to being driven over.
•
Insulation damage due to being ripped out of the
wall outlet.
•
Cracks due to the insulation ageing.
Such damaged electrical connection cables must not
be used and are life-threatening due to the insulation
damage.
Check the electrical connection cables for damage regu-
larly. Make sure that the connection cable does not hang
on the power network during the inspection.
Electrical connection cables must comply with the ap-
plicable VDE and DIN provisions. Only use connection
cables with the marking „H05VV-F“.
The printing of the type designation on the connection
cable is mandatory.
AC motor
•
The mains voltage must be 230 V~
•
Extension cables up to 25 m long must have a
cross-section of 1.5 mm
2
.
Connections and repairs of electrical equipment may
only be carried out by an electrician.
Cross Cut
This saw has 2 options for making cross cuts:
Using the sliding mitre gauge or using the sliding car-
riage.
Sliding mitre gauge, Fig. 27
The sliding mitre gauge is most suitable for cutting small
pieces. It fits into either of the T-shaped channels in
the table. To set 90 degrees or any other angle, undo
the locking knob and rotate the quadrant to the desired
angle. The work piece can be held against either face of
the fence
Sliding table Fig. 28, 29
The sliding table is more suitable when working with
large flat panels.
To use the sliding table pull the table all the way forward.
Set the rip fence for sliding table to the desired width of
cut.
If an angle is to be cut, undo the thumb screw and
ratchet lever, swing the rip fence to the desired angle
and lock them both off.
If necessary, undo both thumb screws and adjust the rip
fence so that the plastic tip is just clear of the blade.
Load the wood onto the sliding table and screw down
the workpiece clamp to secure it. Press the start button
and push the wood through the saw blade.
An alternative configuration is available for the sliding ta
-
ble. The fence can be assembled onto the back edge of
the table in a mirror image of the standard configuration.
The work piece is loaded against the back edge of the
fence and then fed onto the blade.
Using this configuration, the crosscut capacity can be
increased and the sliding table rip fence can be moved
backwards so that it does not obstruct the operator.
Transport
1. Turn off the power tool before any transport and
disconnect it from the power supply.
2. Apply the power tool at least with two people, do
not touch the table extensions.
3.
Protect the power tool from knocks, bumps and
strong vibrations, such as during transport in vehi-
cles.
4. Secure the power tool against overturning and slid-
ing.
5. Never use the safety devices for handling or trans-
porting purposes.
Maintenance
m
Warning!
Prior to any adjustment, maintenance or
service work disconnect the mains power plug!
General maintenance measures
•
Keep all safety devices, air vents and the motor hous-
ing free of dirt and dust as far as possible. Wipe the
equipment with a clean cloth or blow it down with com-
pressed air at low pressure.
•
We recommend that you clean the equipment imme-
diately after you use it.
•
Clean the equipment regularly with a damp cloth and
some soft soap. Do not use cleaning agents or sol-
vents; these may be aggressive to the plastic parts in
the equipment. Ensure that no water can get into the
interior of the equipment.
•
In order to extend the service life of the tool, oil the
rotary parts once monthly. Do not oil the motor.
Содержание 5901309903
Страница 8: ...www scheppach com service scheppach com 49 08223 4002 99 49 08223 4002 58 28 29 8 36 30...
Страница 9: ...www scheppach com service scheppach com 49 08223 4002 99 49 08223 4002 58 9 36...
Страница 20: ...www scheppach com service scheppach com 49 08223 4002 99 49 08223 4002 58 20 36...
Страница 30: ...www scheppach com service scheppach com 49 08223 4002 99 49 08223 4002 58 30 36...
Страница 31: ...www scheppach com service scheppach com 49 08223 4002 99 49 08223 4002 58 31 36...
Страница 32: ...www scheppach com service scheppach com 49 08223 4002 99 49 08223 4002 58 32 36...
Страница 33: ...www scheppach com service scheppach com 49 08223 4002 99 49 08223 4002 58 33 36...