11.
Figure 117: Remove the wire break resistors
12.
Figure 118: Insert the wire break resistors
Take two suitable wire break resistors
(see step 7) from the supplied bag.
Insert the two wire break resistors into
the circuit board. Make sure that you
insert the resistors as far as they will go.
13.
Figure 119: Install the terminal box
14.
Figure 120: Attach the plug-in connector
Mount the new terminal box with the
supplied washers and screws. Tighten
the screw connection to 2 Nm
(crosswise).
Attach the plug-in connector. Tighten the
union nut on the plug-in connector
clockwise.
.