Operating manual for the VISATRON VN2020
V2.0 12/2021 EN
Page
56
of
106
SCHALLER AUTOMATION
66440 Blieskastel / Saarland / Germany / Industriering 14 / P.O. Box 1280
Industrielle Automationstechnik GmbH & Co. KG
T
el. +49(0)6842-508
-
0
/ Fax -260 / Email: [email protected] /
www.schaller-automation.com
Description
Interval (whichever occurs first)
S
tep
s
Hours
4,000
8,000
12
,00
0
16
,00
0
S
e
e
S
e
ctio
n
Req
u
ir
e
d
p
a
rts/to
o
ls
Or months
6 12 18 24
1.
Check negative pressure in the
measuring head:
➔
below 55 mmH2O (5.5mbar)
➔
Adjust negative pressure
➔
Between 55 mmH2O and
65 mmH2O
➔
OK
➔
Between 65 mmH2O and
85 mmH2O
➔
Adjust negative pressure
➔
Above 85 mmH2O
➔
Check the pressure at the
filter control valve
X
X
X
X 7.10.1
270532
U-tube manometer
Or
151800
Digital manometer
2.
Clean the light path in the
measuring head
X
X
X
X 9.1.3
151482
Cleaning kit
3.
Function test with smoke tube
X
X
X
X 9.1.4
151780
Smoke Test Box
4.
Replace filter in filter control valve
X
X
X
X 9.1.5
155006
Maintenance kit for the VN2020
5.
Replacing the inspection cover
seal
X
X
X
X 9.1.3
155006
Maintenance kit for the VN2020
6.
Replace connection box seal
X
X 9.1.6
155006
Maintenance kit for the VN2020
7.
Clean the suction system with
compressed air
X
X
Compressed air max. 6 bar
8. Replacing the mounting plate seal
X
X
155006
Maintenance kit for the VN2020
9.
Check the bellows and spring
systems between the base plate
and the measuring head for
damage
X
X
*
May need a torch
10. Complete overhaul of the oil mist
detection system
S
155004
Service kit for the VN2020
Key to maintenance measures:
X
– Work that must be completed
S
– Only by authorised and certified Schaller Service.
* If the bellows are damaged, please contact Schaller Service immediately.
Table 3: Maintenance cycles