Programming
BASCSOUL_EN
V02 | 10.2017
94
8.4.1
System (Caretaker)
"Grinder/brewing unit" menu item
Display text
Description
Setting range
Notes
Capacity
Sets the number of cycles until the "Empty
grounds container" message appears.
► Set the "Under-counter grounds dispos-
al" to [0].
► Enter the standard setting of 60 cycles.
After 60 cycles, the "Empty grounds
container" message appears.
0 – 100
The standard setting is
[60].
Do not exceed the stan-
dard setting of [60] cof-
fee cakes. The machine
blocks dispensing of
coffee beverages after
65 brewing cycles (5)
until the grounds contai-
ner is emptied.
Grounds container
emptying time
Sets the period of time until the "Current
grounds container counter" is set back to
[0] after it is emptied.
► Empty the grounds container.
► Reinsert the emptied grounds contain-
er.
The counter is reset to [0] after
[5 sec], for example.
0 – 30
–
Current grounds conta-
iner counter
Information on the brewing cycles executed
since the last time the grounds container
was emptied.
–
No setting is available.
Centre grinder calibrati-
on value for 10 sec
The calibration value displayed for 10 sec is
detected during calibration and also dis-
played in this parameter.
The calibration value in [ g ] displayed in
this parameter can be changed without ca-
librating the grinder.
–
Adjusting the calibration
value influences all cof-
fee recipes.
See "Service" –
Calibrate grinder".
Right grinder calibrati-
on value for 10 sec
See above parameter, "Centre grinder cali-
bration value for 10 sec".
–
–
"Milk system" menu item
Display text
Description
Setting range
Notes
Milk container hose
length
Milk hose measurement setting
The hose length of the milk container to the
squeeze valve in the machine is set by the
service technician.
0 – 200
The standard setting is
[37 cm]