Product description
BASCSOUL_EN
V02 | 10.2017
18
3.4
Technical data
Payment systems*
(*) The Payment systems option is not yet
available.
Commercially available payment systems
according to the MDB standard can be
connected.
Possible interfaces:
•
MDB-S
•
DIVA2
•
DIVA2 Max
Connection to dispensing equipment and
cash register systems:
•
Via E protocol
•
Via CSI protocol
Coin and token testers or coin changers can
be placed to the right or left of the machine.
The "Payment systems" option can be retro-
fitted.
Waste water outlet hose
holder
Optimises waste water drainage and pre-
vents it from flowing back.
The holder is attached to the waste water
outlet on the building side.
The end of the waste water hose can be fa-
stened on the holder for optimal drainage.
External waste water / drin-
king water tank monitored
The coffee machine can be used as a mobile
unit thanks to the optional device with the ex-
ternal waste water / drinking water tank.
Both tanks features level monitoring and can
be retrofitted from software version v2.0.
Example
Option
Description
Nominal power* Schaerer Coffee Soul
Steam boiler
Hot water boiler
3000 W
3000 W
Operating temperature
Steam boiler
Hot water boiler
Minimum operating temperature (T min.)
10°C
10°C
Maximum operating temperature (T max.)
192°C
192°C
Operating temperature
140°C
95°C
Overpressure
Steam boiler
Hot water boiler
Working overpressure
2.5 bar
2.5 bar
Permissible working overpressure (p max)
12 bar
12 bar