maximum difference and where was the position of TPS when they
occur.
B=Max Difference found
C=Position TPS1
D=Position TPS2
Isens
: Is the current that require the sensor to work,
Tps Swap
: The device cant detect if the TPS1 and the TPS2 are
inverted. This data generally is a permanent property of body, but a
mistake in the connection can be exposed here.
“no-swap” Means TPS1=TPS1 and TPS2=TPS2
“swap” Means TPS1=TPS2 and TPS2=TPS1
I_coil max
: Max current demanded by motor. To discard short circuit
or gear damaged.
Pol coil: Motor Polarity.
M1+ M2- means that the throttle open when the voltage on
M1 is greater than M2
M1- M2+ means that the throttle open when the voltage on
M2 is greater that M1
Result: Result off analysis. This data must not been taken as absolute
answer, only as orientation.
GOOD, the max difference is lower than 4%.
DOUBT, the max difference is between that 5 and 6%.
BAD the mas difference is greater and can cause problems.
8/36