40
SCAIME Manual : NU-eNod4B-ETH-E-236708-D.docx
11.6.7
Minimum belt speed limit value (0.1%)
Minimum belt speed is the limit value for minimum belt speed in 0.1% of the nominal speed. The entry of the number e.g.
800 corresponds to 80.0 %. After this value has been exceeded,
eNod4
sets the status bit “<min. speed” in
belt alarms
register
.
11.6.8
Maximum belt speed limit value (0.1%)
Maximum belt speed is the limit value for maximum belt speed in 0.1% of the nominal speed. The entry of the number e.g.
1020 corresponds to 102.0%. After this value has been exceeded,
eNod4
sets the status bit “>max. speed” in
belt alarms
register
.
11.6.9
Inhibit time of speed alarms at start (ms)
Monitoring the belt speed is only activated after this delay time when the belt is started.
11.6.10
Inhibit time of speed alarms in service (ms)
When the belt speed is below/above the min/max belt speed, the alarm is activated after this delay elapsed.
11.6.11
Errors counter
Any alarm disappears automatically when the origin of the defect disappears. In every emitted alarm, the variable
error
counter
is incremented.
Error counter
variable can only be set to zero using
clear dosing/batch
command.
11.7
Inputs assignments
eNod4
device could have up to
5 Inputs
(with
IO+ option
). One of them is especially reserved for
speed sensor
input. All
others logical inputs can be assigned to functional dosing process commands. All process commands have edge functioning.