75
SCAIME Manual : NU-eNod4B-ETH-E-236708-D.docx
The Band Length Calibration is available on page 2 of the ' Conveyor Settings ' pressing
When the system is running empty, this command will cause eNod4 to initiate belt length calibration sequence.
An internal timer is restarting and the calibration procedure duration will depend of the current belt speed, the belt length
and the number of revolutions to handle.
Important: Before initiated belt length calibration procedure, user has to configure the following parameters:
•
Maximum pulses per meter (see next §)
•
Number of revolutions
12.2.4
Speed
Parameter
Possible Value
Description
Speed Parameters
Speed Target
0.00 – 655.35 m/s
Defines the nominal speed in m/s. eNod4 determines nominal belt load
from nominal speed and nominal flow rate.
Speed stabilization
time at start
0 – 65535 sec
In weigh feeder mode and if PID function is done through the belt speed,
this is the stabilization time before PID activation.
User fixed Speed *
0.00 – 655.35 m/s Defines the belt speed in m/s if no speed sensor is connected to eNod4.
Maximum pulses per
meter
0 - 65535
Defines constant maximum pulses number of speed sensor.
Speed determination
time factor
1 – 65535
(250ms)
Specifies the belt speed determination time in multiple of 250ms.