![Scaime eNod4-B Скачать руководство пользователя страница 53](http://html1.mh-extra.com/html/scaime/enod4-b/enod4-b_manual_1205995053.webp)
53
SCAIME Manual : NU-eNod4B-ETH-E-236708-D.docx
Parameter
Possible Value
Description
Calibration Parameters
Range
0 – 10 000 000
Maximum weighing capacity
Division
1, 2, 5, 10, 20, 50
Difference between two consecutive indicated values
Decimals
0-7
Position of decimal point
Weight unit
4 visible char
Weight measurement unit (g, kg, t, lb…) using for calibration
Time unit
s, mn, h
Time unit using for calibration (eNod4-F and B). Only s and h can be
selected in eNod4-B.
Weight unit (display
flow rate)
g, kg, t
Weight unit of flow rate which is displayed on main screen.
Time unit (display
flow rate)
s, mn, h
Time unit of flow rate which is displayed on main screen.
Cut-off frequency
(display flow rate)
Cut-off frequency of flow rate which is displayed on main screen.