13
■
T1-02: Motor Rated Power
It sets the motor rated power according to the motor nameplate value.
No.
Parameter Name
Setting Range
Default
T1-02
Motor Rated Power
0 to 10
5.3 kW
■
T1-03: Motor Rated Voltage
It sets the motor rated voltage according to the motor nameplate value.
No.
Parameter Name
Setting Range
Default
T1-03
Motor Rated Voltage
0 to 380
380 V
■
T1-04: Motor Rated Current
It sets the motor rated current according to the motor nameplate value. Enter the current at the motor
base speed.
No.
Parameter Name
Setting Range
Default
T1-04
Motor Rated Current
2 to 24 A
12 A
■
T1-05: Motor Base Frequency
It sets the motor rated frequency according to the motor nameplate value.
No.
Parameter Name
Setting Range
Default
T1-05
Motor Base Frequency
0 to 50 Hz
50 Hz
■
T1-06: Number of Motor Poles
It sets the number of motor poles according to the motor nameplate value.
No.
Parameter Name
Setting Range
Default
T1-06
Number of Motor Poles
2 to 48
4
■
T1-07: Motor Base Speed
It sets the motor rated speed according to the motor nameplate value.
No.
Parameter Name
Setting Range
Default
T1-07
Motor Base Speed
300 to 3000 rpm
1380 rpm
■
T1-08: Encoder resolution (pulses per revolution)
It sets the number of pulses from the PG encoder. Set the actual number of pulses for one full motor
rotation.
No.
Parameter Name
Setting Range
Default
T1-08
Encoder number of Pulses Per Revolution
0 to 30000 ppr
2048