Appendix A: Parameters

 

Table 

Setting Parameters

No. 

Name 

Unit 

Default 

value 

No. 

Name 

Unit 

Default 

Value 

A1-02 

Control Method Selection 

E1-12 

Voltage at 4/32 Max Speed 

35 

A1-03 

Reset Factory 

E1-13 

Voltage at 3/32 Max Speed 

20 

b1-02 

Up/Down Command Selection 

E2-01 

Motor Rated Current 

12 

b1-08 

Up/Down Command Selection 

while in Programming Mode 

E2-02 

Motor Rated Slip 

Hz 

C1-01 

Acceleration Ramp 1 

E2-03 

Motor No-load current 

C1-02 

Deceleration Ramp 1 

E2-04 

Number of Motor Poles 

C1-04 

Deceleration Ramp 2 

E2-05 

Motor Line to Line Resistance 

Ω 

C1-09 

Fast Stop Ramp 

E2-11 

Motor Rated Power 

kW 

5.3 

C1-15 

Inspection Deceleration Ramp 

H1-03 

Multi-Function Digital Input 

Terminal S3 Function Selection 

C2-01 

Jerk at Accel Start 

H1-04 

Multi-Function Digital Input 

Terminal S4 Function Selection 

C2-02 

Jerk at Accel End 

H1-05 

Multi-Function Digital Input 

Terminal S5 Function Selection 

C2-03 

Jerk at Decel Start 

H1-06 

Multi-Function Digital Input 

Terminal S6 Function Selection 

C2-04 

Jerk at Decel End 

L1-02 

Motor Overload Protection Time 

60 

C2-05 

Jerk below Leveling Speed 

L1-08 

oL1 Current Level 

150 

C4-01 

Torque Compensation Gain 

1.5 

L5-01 

Number of Auto Reset Attempts 

C4-02 

Torque Compensation 

Primary Delay time 

ms 

200 

o3-01 

Copy Function Selection 

d1-01 

Speed Reference 1 

Hz 

10 

o3-02 

Copy Allowed Selection 

d1-02 

Speed Reference 2 

Hz 

S1-00 

Zero Speed Level at Start 

Hz 

d1-03 

Speed Reference 3 

Hz 

S1-01 

Zero Speed Level at Stop 

Hz 

0.5 

d1-04 

Speed Reference 4 

Hz 

S1-02 

DC Injection Current at Start 

70 

d1-05 

Speed Reference 5 

Hz 

S1-03 

DC Injection Current at Stop 

80 

d1-06 

Speed Reference 6 

Hz 

S1-04 

DC Injection/Position Lock Time at 

Start 

0.4 

d1-07 

Speed Reference 7 

Hz 

S1-05 

DC Injection/Position Lock Time at 

Stop 

0.6 

d1-08 

Speed Reference 8 

Hz 

S1-06 

Brake Release Delay Time 

0.2 

d1-18 

Speed Reference Selection Mode 

S1-07 

Brake Close Delay Time 

0.3 

d1-19 

Nominal Speed 

Hz 

50 

S1-10 

Run Command Delay Time 

0.2 

d1-20 

Intermediate Speed 1 

Hz 

30 

S1-11 

Output Contactor Open Delay Time 

0.2 

d1-24 

Inspection Operation Speed 

Hz 

15 

S1-12 

Motor Contactor Control During 

Auto-Tuning 

d1-26 

Leveling Speed 

Hz 

S2-01 

Motor Rated Speed 

rpm 

1380 

E1-02 

V/f Mode 

S2-02 

Slip Compensation Gain in 

Motoring Mode 

E1-03 

Voltage Offset 

S2-03 

Slip Compensation Gain in 

Regenerative Mode 

0.5 

E1-04 

Maximum Output Frequency 

Hz 

50 

S2-06 

Slip Compensation Torque 

Detection Filter Time Constant 

2000 

E1-05 

Maximum Voltage 

380 

T1-01 

Auto-Tuning Mode Selection 

E1-06 

Voltage at 16/32 Max Speed 

167 

T1-02 

Motor Rated Power 

kW 

5.5 

E1-07 

Voltage at 12/32 Max Speed 

121 

T1-03 

Motor Rated Voltage 

380 

E1-08 

Voltage at 10/32 Max Speed 

92 

T1-04 

Motor Rated Current 

12 

E1-09 

Voltage at 8/32 Max Speed 

75 

T1-05 

Motor Base Frequency 

Hz 

50 

E1-10 

Voltage at 6/32 Max Speed 

52 

T1-06 

Number of Motor Poles 

E1-11 

Voltage at 5/32 Max Speed 

40 

T1-07 

Motor Base Speed 

rpm 

1380 



Содержание L450S

Страница 1: ...User Manual L450U L450S...

Страница 2: ...this manual all functions are introduced and explained in detail The first chapter is dedicated to the initial settings and Auto tuning which calculates control parameters required to drive the AC mot...

Страница 3: ...Hz Output Voltage V 3 phase 0 380V 0 100 Hz Rated Current A 14 18 24 31 Weight Kg 5 3 5 4 5 7 6 0 Mechanical Installation Dimensions The drive dimensions needed for mechanical installation are mentio...

Страница 4: ...rive control circuits in SBT L450U and L450S models respectively In L450S model the drive can be used in a single phase It is also possible to set and run the drive via the digital operator without co...

Страница 5: ...7 Figure 2 2 b SBT L450S I O block diagram...

Страница 6: ...to display the previous item select parameter numbers and decrements setting values 7 STOP Key Stops drive operation 8 ENTER Key Enters parameter values and settings Selects a menu item to move betwee...

Страница 7: ...REV During Down command 8 Function Key 2 F2 FWD REV Pressing switches between Up and Down when the Up Down command is set using the digital operator DATA Pressing scrolls to the next display Pressing...

Страница 8: ...alue Input Parameter Unit Tuning Type T1 01 3 Stationary 10 Encoder offset calculation Motor Rated Power T1 02 kW Yes Yes Motor Rated Voltage T1 03 Vac Yes Yes Motor Rated Current T1 04 A Yes Yes Moto...

Страница 9: ...l display appears 2 Press or until the Auto Tuning display appears 3 Press to begin setting parameters 4 Press to select the value for T1 01 5 Save the setting by pressing 6 The display automatically...

Страница 10: ...e motor stopped which could result in death or serious injury Do not touch the motor until Auto Tuning has been completed Step Display Result 1 After entering the data listed on the motor nameplate pr...

Страница 11: ...Frequency It sets the motor rated frequency according to the motor nameplate value No Parameter Name Setting Range Default T1 05 Motor Base Frequency 0 to 50 Hz 50 Hz T1 06 Number of Motor Poles It s...

Страница 12: ...e more precise speed control and quicker torque response than V f Setting 3 Closed Loop Control Use this mode to drive an induction motor with encoder feedback This mode offers high performance contro...

Страница 13: ...efault b3 01 Detection light load direction 0 1 1 Setting 0 Disable If this parameter is set to 0 the drive will move in the direction that has been issued from the control center while the drive itse...

Страница 14: ...speed 2 C1 04 Deceleration Ramp 2 Leveling speed to zero speed 2 C1 09 Fast Stop Ramp Nominal speed to zero speed 0 C1 15 Inspection Deceleration Ramp Sets the deceleration ramp during Inspection Run...

Страница 15: ...t the torque compensation gain in small steps of 0 05 in the following situations Increase this setting when using a long motor cable or when the starting torque is not high enough to accelerate the m...

Страница 16: ...C5 03 Speed Control Loop Proportional Gain 2 0 to 255 15 C5 04 Speed Control Loop Integral Time 2 0 to 8191ms 1000ms C5 13 Speed Control Loop Proportional Gain 3 0 to 255 15 C5 14 Speed Control Loop I...

Страница 17: ...ference d1 Speed Reference The parameters of this family adjust the reference speed of the drive in different conditions d1 01 to d1 08 Speed References 1 to 8 The drive lets the user switch between 8...

Страница 18: ...and leveling speed activated at the same time the leveling speed has priority over speed parameters d1 19 Nominal Speed Sets the nominal speed and it is used as the motor reference speed when a digit...

Страница 19: ...r heavy loads Besides voltage offset could be added to all points in the curve by using E1 03 The voltages speed curve will be according to Fig 2 2 Use this option when the motor is under heavy loads...

Страница 20: ...t for the motor in amperes when operating at the rated frequency The drive sets E2 03 during the Auto Tuning process Please note that if this parameter is set to 0 output phase loss fault detection wi...

Страница 21: ...rminal S5 Function Selection 0 to 14 7 H1 06 Multi Function Digital Input Terminal S6 Function Selection 0 to 14 8 Setting Function 0 Multi Speed Reference 1 1 Multi Speed Reference 2 2 Multi Speed Re...

Страница 22: ...otor coasts to stop After disabling the Run command clear the fault either by pressing the RESET key on the digital operator or closing a digital input configured as a Fault Reset H1 13 Note Disable t...

Страница 23: ...justment No Parameter Name Setting Range Default L1 02 Motor Overload Protection Time 6 s to 90 s 60 s L1 08 oL1 Current Level It Sets the current level for motor overload detection This parameter sho...

Страница 24: ...y protection for the digital operator is enabled by default Set o3 02 to 1 to unlock copy protection Setting 2 OP INV WRITE Copies all parameters from the digital operator to the drive Setting 3 OP IN...

Страница 25: ...ult S1 05 DC Injection Time at Stop 0 00 to 10 00 s 0 60 s S1 06 Brake Release Delay Time Determines the time that must pass after an Up Down command is entered before the output terminal set for Brak...

Страница 26: ...erative Mode Slip compensation for leveling speed can be set separately for motoring and regenerative states to help improve the accuracy of leveling No Parameter Name Setting Range Default S2 02 Slip...

Страница 27: ...his value is calculated internally U1 10 Input Terminal Status Displays the input terminal status U1 11 Output Terminal Status Displays the output terminal status U3 01 to U3 08 First to 8th Recent Fa...

Страница 28: ...hile attempting to perform a fault reset The encoder and drive phase sequence are not the same Interchange A B of the encoder Overcurrent OC Drive current exceeded overcurrent detection level The Load...

Страница 29: ...down command has not been removed yet Excessive Speed Deviation dEv The difference between the motor speed feedback and the reference speed is too high The mechanical brake is not released The slope o...

Страница 30: ...lied immediately and the drive output shuts off To tune the drive for the elevator applications the procedure indicated below is recommended Step 1 Up Down Command Source Selection The input source fo...

Страница 31: ...settings defined in parameters d1 19 d1 20 d1 24 and d1 26 can be set and selected using four digital inputs Speed Selection Terminal Details H1 6 Nominal Speed H1 9 Revision Speed H1 7 Intermediate S...

Страница 32: ...01 is used for all accelerations C1 02 is used when the motor decelerates from any speed to any other speed except nominal and leveling speed to zero speed C1 04 is used when the motor decelerates fro...

Страница 33: ...od Selection The control method should be determined based on the requirements and available equipment For more landing accuracy Open loop control is recommended when PG is not available If PG is used...

Страница 34: ...ncrease the Delay Time to Close the Brake S1 07 If necessary also increase the DC Injection Braking Time at Stop S1 05 If the problem still exists increase zero speed at stop S1 01 Motor contactor is...

Страница 35: ...ing in down direction coming from an upper floor and measure note the distance where the lift has stopped from the floor level If the cabin is above the floor level the distance is positive Ex 4mm if...

Страница 36: ...e cabin is empty with less slip the lift will go faster without a load in braking condition in this case decrease S2 03 slip compensation braking gain by 10 and measure again If the stop distance in b...

Страница 37: ...peed Reference 2 Hz 0 S1 00 Zero Speed Level at Start Hz 1 d1 03 Speed Reference 3 Hz 0 S1 01 Zero Speed Level at Stop Hz 0 5 d1 04 Speed Reference 4 Hz 0 S1 02 DC Injection Current at Start 70 d1 05...

Страница 38: ...t Voltage Reference V U1 07 DC Bus Voltage V U1 08 Output Power kW U1 10 Input Terminal Status U1 11 Output Terminal Status U3 01 to U3 08 Fault History 1 to 8 U6 01 Motor Secondary Current Iq A U6 02...

Страница 39: ...ve Motor rotation Yes Waiting for H and Hc connections Yes No To view the command given to S1 to S 6 can use the Monitor parameter from parameter U1 10 Also the parameter U1 01 in the monitor section...

Страница 40: ...49 Address No 126 Noavari 12 Noavari St Pardis Technology Park Damavand Rd Tehran Iran Tel 98 21 76251431 98 21 76250959 Fax 98 21 76250298...

Отзывы: