Document
9911004rev27
Title
Date
2017-02-16
Page
72(81)
SBS MicroSMART Battery Charger Technical Handbook
11.
Appendix 4, Statistic logs
The statistic logs are stored in the charger available for read out using the SBS MicroSMART
Service tool.
11.1.
History log
Charger ID
Charger identifier. Configurable via the charger
menu system or
Advanced, Configure charger
in
Service tool.
Customer
Customer
entered at import of data.
Fleet
Fleet
entered at import of data.
Charge index
The charge index since last
Clear statistics
was
performed in the charger.
Charging mode
The source of the charging parameters. The
possible values are:
•
User def, user defined parameters in the
service menu.
•
BM, parameters have been uploaded from the
battery monitoring unit.
In the charger this is displayed as
Source
.
Charge start time
The date and time when the charge cycle was
started, i.e. battery connected.
Charger local time.
Charge end time
The date and time when the charge cycle was
ended, i.e. battery disconnected.
Charger local time.
Charge duration
The difference between
Charge start time
and
Charge end time
.
Maximum 99 hours.
Active charge time
Time between
Charge start time
and
Charge end
time
when the power unit has been active.
Maximum 99 hours.
Totally charged Ah
Ampere hours charged between
Charge start time
and
Charge end time
.
Totally charged Wh
Watt hours charged between
Charge start time
and
Charge end time
.
Charged Ah, main (%)
Ampere hours in percent of capacity charged in
main charging phase.
Cycles with
Charged Ah, main
below 1 Ah aren’t
stored as a log.
Start VPC (V)
Actual battery voltage per cell when the battery
was connected to the charger. Measured before
start of charge.