33
When the multi-function input terminal is set to be used to switch 1
st
and 2
nd
Acc/Dec time and can work, then
the AC drive will decelerate according to the 2
st
Deceleration time.This parameter is determined by the time which
the AC motor drive required when it decelerate from [max. frequency] (01-02) to 0 Hz. The rate is linear unless S
Curve is “Enabled.
01-15
Motor Stop mode selection
Factory setting
0
Setting range
0:Deceleration and stop
1:Coast to a stop
After STOP reference received, the AC motor drive shall control the motor to stop as parameter set.
Deceleration and stop:according to deceleration time set by 1-12 or 1-14, AC motor drive decelerate to min output
frequency(1-07) and then machine stops.
Coast to a stop:AC motor drive stops output immediately and motor runs freely in load inertia and then stops
Deceleration and stops Coasting
01-16
Inhibit REV rotation function setting
Factory setting
0
Setting range
0:REV rotation available
1:REV rotation inhibited
This parameter is set to the AC motor drive whether can perform the function of reverse operation.
01-17
Carrier frequency selection
Factory setting
2
Setting range
0:fc=3kHz
1:fc=6kHz
2:fc=8kHz
3:fc=10kHz
4:fc=12kHz
5:fc=15kHz
This parameter determines the PWM (Pulse Width Modulation) output carrier frequency .
Carrier frequency
Electromagnetic noise
Noise,Spill current
Heat dissipation
Current Waveform
1 kHz
big
small
small
big
small
big
8 kHz