![Savch S200 Series Скачать руководство пользователя страница 22](http://html.mh-extra.com/html/savch/s200-series/s200-series_user-manual_1203756022.webp)
18
Display Project
Description
Showing the current set frequency of AC motor drive. Reference of this frequency may
from [Master Frequency Setting], [Jog Run Frequency] or [Multi-step Reference 1 to 7]
controlled by external terminals 1, 2 and 3. If frequency reference comes from digital
control panel, frequency can be set directly by depressing
/
.
Displaying actual frequency output from AC motor drive to motor
Displaying physical quantity(u) defined by users
Displaying count value(C) of internal counter
Displaying output current of U, V and W at output side of the AC motor drive
Displaying parameter project. Content of this parameter shall be displayed by
depressing
PRGM
DATA
.
Displaying parameter content value. Modified materials shall be stored by depressing
PRGM
DATA
.
If END information (as diagram left shows) lasts for about 1 sec, it means that data has
been received and memorized automatically. If data needs modifying, it shall be
completed by acting directly with
/
and depress
PRGM
DATA
key again.
3.2 LED Monitor Descriptions
Red light shows Forward
RUN STOP JOG FWD REV
Red light shows Inversion
Red light shows JOG
Red light shows Stop
Red light shows Run